A potentiometric aluminium sensor, based on the use N,N'-bis(salicylidene)-1,2-cydohexanediamine (NBSC) as a neutral carrier, in poly(vinyl chloride) (PVC) matrix, is reported. Effect of various plas-ticizers; 2-nitrophenyloctylether (o-NPOE), tri-n-butyl phosphates (TBP), dioctylpththalate (DOP) & chloronapthalen (CN), and anion excluder, sodium tetraphenylborate (NaTPB) was studied. The best performance was obtained with a membrane composition of PVC: o-NPOE: NBSC: NaTPB ratio (w/w; mg) of 150:150:5:5. The sensor exhibits significantly enhanced selectivity toward Al{sup}(3+) ions over the concentration range 1.0×10{sup}(-8)-1.0×10{sup}(-1) M with a lower detection limit of 5.0×10{sup}(-9) M and a Nernstian slope of 20.3 ±0.1 mV decade{sup}(-1) of activity. Influence of the membrane composition and possible interfering ions was investigated on the response properties of the electrode. Fast and stable response, good reproducibility and long-term stability are demonstrated. The sensor shows response time of <5 s and can be used for about 3 months without any considerable divergence in their potential response. Selectivity coefficients determined by matched potential method (MPM) indicate high selectivity for aluminium (III) ion. The proposed electrode shows fairly good discrimination of aluminium (HI) from many metal ions. It was successfully applied for direct determination of aluminium (HI) in biological, industrial and environmental samples. The electrode can be used in the pH range of 2.0-9.0 and mixtures containing up to 20% (v/v) non-aqueous content. It was used as an indicator electrode in potentiometric titration of aluminium ion vs. EDTA.
机译:据报道,在聚氯乙烯(PVC)基质中,使用N,N'-双(水杨基)-1,2-环己烷二胺(NBSC)作为中性载体的铝电位计。各种增塑剂的作用;研究了2-硝基苯基辛基醚(o-NPOE),磷酸三正丁酯(TBP),邻苯二甲酸二辛基酯(DOP)和氯萘酚(CN)以及阴离子排斥剂四苯基硼酸钠(NaTPB)。用PVC∶o-NPOE∶NBSC∶NaTPB之比(w / w; mg)为150∶150∶5∶5的膜组成可获得最佳性能。在浓度范围1.0×10 {sup}(-8)-1.0×10 {sup}(-1)M范围内,传感器对Al {sup}(3+)离子的选择性显着提高,检测极限为5.0× 10 {sup}(-9)M和20.3±0.1 mV十年的Nernstian斜率活动{sup}(-1)。研究了膜组成和可能的干扰离子对电极响应特性的影响。证明了快速稳定的响应,良好的重现性和长期稳定性。该传感器的响应时间小于5秒,可以使用大约3个月,其潜在响应没有任何明显的差异。通过匹配电势方法(MPM)确定的选择性系数表明对铝(III)离子具有高选择性。拟议中的电极显示出铝(HI)与许多金属离子的良好区分度。它已成功应用于生物,工业和环境样品中铝的直接测定。电极可在2.0-9.0的pH范围内使用,混合物中最多可包含20%(v / v)的非水成分。它用作铝离子对EDTA的电位滴定中的指示电极。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号