首页> 外文期刊>Contraception >Copper-containing, framed intrauterine devices for contraception: a systematic review of randomized controlled trials.
【24h】

Copper-containing, framed intrauterine devices for contraception: a systematic review of randomized controlled trials.

机译:含铜框架式宫内节育器:随机对照试验的系统综述。

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND: Intrauterine devices (IUDs) are safe and effective methods of long-term reversible contraception. The design and copper content as well as placement of the copper on IUDs could affect their effectiveness and side effect profile. We compared different copper IUDs for their effectiveness and side effects. STUDY DESIGN: We searched multiple electronic databases with appropriate keywords and names of the IUDs known to be on the market. We searched the reference lists of papers identified and contacted authors when possible. There was no language restriction. Randomized controlled trials comparing different IUDs that reported on clinical outcomes were considered for inclusion. Two reviewers independently extracted data on outcomes and trial characteristics. We combined the trial results in meta-analyses and expressed results as rate difference (RD) using a fixed-effects model with 95% confidence interval (CI). In the presence of significant heterogeneity, a random-effects model was applied. RESULTS: We included 35 trials, resulting in 18 comparisons of 10 different IUDs in approximately 48,000 women. TCu380A was more effective in preventing pregnancy than MLCu375 (RD 1.70%, 95% CI 0.07-2.95% after 4 years of use). TCu380A was also more effective than MLCu250, TCu220 and TCu200. There tended to be fewer pregnancies with TCu380S compared to TCu380A after the first year of use, a difference which was statistically significant in the fourth year (RD -1.62%, 95% CI -3.00% to -0.24%). This occurred despite more expulsions with TCu380S (RD 3.50%, 95% CI 0.36-6.63% at 4 years). MLCu375 was no more effective than TCu220 at 1 year of use, or MLCu250 and NovaT up to 3 years. Compared to TCu380A or TCu380S, none of the IUDs showed any benefits in terms of bleeding or pain or any of the other reasons for early discontinuation. None of the trials that reported events at insertion found one IUD easier to insert than another or caused less pain at insertion. There is no evidence that uterine perforation rates vary by type of device. There are minimal randomized data on IUD use in nulliparous women. CONCLUSIONS: TCu380A and TCu380S appear to be more effective than other IUDs. No IUD showed consistently lower removal rates for bleeding and pain in comparison to other IUDs. There is no evidence that any particular framed copper device is better suited to women who have not had children.
机译:背景:宫内节育器(IUD)是长期可逆避孕的安全有效方法。 IUD的设计和铜含量以及铜的放置可能会影响其有效性和副作用。我们比较了不同铜制宫内节育器的有效性和副作用。研究设计:我们搜索了多个电子数据库,其中包含适当的关键字和已知在市场上出售的宫内节育器的名称。我们在可能的情况下搜索了已鉴定论文的参考清单并与作者联系。没有语言限制。纳入比较临床报告的不同宫内节育器的随机对照试验被认为包括在内。两名审稿人独立提取了有关结果和试验特征的数据。我们将试验结果纳入荟萃分析,并使用具有95%置信区间(CI)的固定效应模型将结果表示为比率差异(RD)。在存在明显异质性的情况下,应用了随机效应模型。结果:我们纳入了35个试验,对约48,000名妇女的10种不同宫内节育器进行了18次比较。 TCu380A在预防怀孕方面比MLCu375更有效(使用4年后,RD 1.70%,95%CI 0.07-2.95%)。 TCu380A也比MLCu250,TCu220和TCu200更有效。使用第一年后,与TCu380A相比,TCu380S的妊娠率往往较少,这在第四年具有统计学意义(RD -1.62%,95%CI -3.00%至-0.24%)。尽管用TCu380S驱逐出院的次数更多(RD 3.5%,4年95%CI 0.36-6.63%)。在使用1年时,MLCu375的疗效不及TCu220或3年以下的MLCu250和NovaT更有效。与TCu380A或TCu380S相比,没有一种宫内节育器在出血或疼痛或其他任何早期停药方面没有任何益处。没有一项报道插入事件的试验发现,一个IUD比另一枚更容易插入,或者插入时引起的疼痛更少。没有证据表明子宫穿孔率随设备类型而异。关于未产妇使用宫内节育器的随机数据很少。结论:TCu380A和TCu380S似乎比其他宫内节育器更有效。与其他宫内节育器相比,没有宫内节育器表现出持续较低的出血和疼痛清除率。没有证据表明任何特定的带框铜制装置更适合没有孩子的女性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号