首页> 外文期刊>Analytica chimica acta >Effect of extraction temperature on pressurized liquid extraction of polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls from a sediment sample using polar and non-polar solvents
【24h】

Effect of extraction temperature on pressurized liquid extraction of polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls from a sediment sample using polar and non-polar solvents

机译:萃取温度对使用极性和非极性溶剂从沉积物样品中加压萃取多氯二苯并对二恶英,多氯二苯并呋喃和类二恶英类多氯联苯的影响

获取原文
获取原文并翻译 | 示例
       

摘要

This study is the first to investigate the effect of extraction temperature (150,175, and 200°C) on the simultaneous pressurized liquid extraction (PLE) of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (DL-PCBs) from a sediment sample (certified reference material: JSAC 0431). To provide basic data that will help to determine the optimum conditions for PLE, six single solvents (toluene, dichloromethane [DCM], benzene, acetoni-trile, acetone, and methanol) were used as an extraction solvent. The results obtained by PLE with each solvent were compared with those obtained by Soxhlet extraction using toluene. The efficiency of PLE for 2,3,7,8-substituted PCDDs, 2,3,7,8-substituted PCDFs, and DL-PCBs, as obtained by PLE using the solvents toluene, DCM, benzene, and acetonitrile, showed an increase with increasing extraction temperature. The recoveries of PCDDs, PCDFs, and DL-PCBs obtained by PLE using toluene were similar to or inferior to those obtained using the Soxhlet method. In contrast, their recoveries obtained by PLE using DCM, benzene, and acetonitrile were similar to or higher than those obtained using the Soxhlet method. Notably, the recoveries of PCDDs, PCDFs, and DL-PCBs using benzene at 200°C were 117 ± 15, 123 ± 13, and 115 ± 12%, respectively. When using acetone and toluene, the recoveries of tetra-hexaCDDs and tetra-hexaCDFs also increased with extraction temperature. In particular, the recoveries of 2,3,7,8-tetraCDD and 2,3,7,8-tetraCDF obtained with acetone at 200 °C were 181 ± 21 and 167 ± 14%, respectively. However, the efficiency of PLE for heptaCDDs and/or heptaCDFs was insufficient at all the tested temperatures. Furthermore, the efficiency of PLE for octaCDD and/or octaCDF showed a pronounced decrease with increasing extraction temperature, yielding recoveries of approximately 40% at 200 °C. We found that heptaCDF isomers were produced from authentic octaCDF during the PLE procedure with acetone at 200 °C, indicating that the lower recoveries of highly chlorinated DDs and/or DFs are attributable to their degradation.
机译:这项研究是第一个研究提取温度(150,175和200°C)对同时加压的多氯二苯并对二恶英-二恶英(PCDDs),多氯二苯并呋喃(PCDFs)和类似二恶英的液体萃取(PLE)的影响的研究沉积物样品中的多氯联苯(DL-PCBs)(认证参考材料:JSAC 0431)。为了提供有助于确定PLE最佳条件的基本数据,使用了六种单一溶剂(甲苯,二氯甲烷[DCM],苯,乙腈,丙酮和甲醇)作为萃取溶剂。将通过PLE在每种溶剂下获得的结果与通过使用甲苯进行索氏提取的结果进行比较。 PLE对2,3,7,8取代的PCDD,2,3,7,8取代的PCDF和DL-PCB的效率由PLE使用溶剂甲苯,DCM,苯和乙腈获得随着提取温度的升高而增加。通过PLE使用甲苯获得的PCDD,PCDF和DL-PCB的回收率与使用索氏提取法获得的回收率相似或逊色。相反,通过PLE使用DCM,苯和乙腈获得的回收率与使用索氏提取法获得的回收率相似或更高。值得注意的是,使用苯在200°C下的PCDDs,PCDFs和DL-PCBs的回收率分别为117±15、123±13和115±12%。当使用丙酮和甲苯时,四六六CDD和四六六CDF的回收率也随萃取温度的增加而增加。特别地,用丙酮在200°C下获得的2,3,7,8-tetraCDD和2,3,7,8-tetraCDF的回收率分别为181±21%和167±14%。但是,PLE对heptaCDD和/或heptaCDF的效率在所有测试温度下均不足。此外,PLE对octaCDD和/或octaCDF的效率随着提取温度的升高而显着降低,在200°C时回收率约为40%。我们发现heptaCDF异构体是在PLE程序中在200°C的丙酮条件下从真正的octaCDF产生的,这表明高氯化度DD和/或DF的较低回收率是由于它们的降解所致。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号