Solution studies on the binding properties of uranyl ion toward four different recently synthesized benzo-substituted macrocyclic diamides L1-L4 revealed the occurrence of a 1:1 complexation of the ligands with UO_2~(2+)ion,with a stability order of L2>L1>L4>L3.Consequently,L2 was used as a suitable neutral ionophore for the preparation of novel polymeric membrane(PME)and coated graphite(CGE)UO_2~(2+)-selective electrodes.The electrodes exhibit a Nernstian behavior for UO_2~(2+)ions over wide concentration ranges(1.0×10~(-6)-1.0×10~(-1)M for PME and 1.0×10~(-7)-1.0×10~(-1)M for CGE)and very low limits of detection(8.0×10~(-7)M for PME and 7.3×10~(-8)M for CGE).The proposed potentio metric sensors manifest advantages of fast response and,most importantly,good selectivity with respect to many alkali,alkaline earth,transition,and heavy metal ions.The potentiometric responses of the electrodes are independent of the pH of the test solution in the pH range 2.9-3.7.The CGE was used in flow injection potentiometry and resulted in well defined peaks for uranyl ions with stable baseline,excellent reproducibility and very high sampling rate of 170 injections per hour.The proposed FIP system was used for the determination of trace uranyl ions in real and synthetic samples.
机译:对铀酰离子与最近合成的四种不同的苯并取代的大环二酰胺L1-L4的结合特性的溶液研究表明,配体与UO_2〜(2+)离子发生1:1络合,稳定性顺序为L2> L1> L4> L3。因此,L2被用作制备新型聚合物膜(PME)和包覆石墨(CGE)UO_2〜(2+)选择电极的合适中性离子载体。该电极对UO_2具有Nernstian行为〜(2+)离子在宽浓度范围内(对于PME为1.0×10〜(-6)-1.0×10〜(-1)M和1.0×10〜(-7)-1.0×10〜(-1)M对于CGE)和极低的检出限(PME为8.0×10〜(-7)M,CGE为7.3×10〜(-8)M)。所提出的电位传感器具有响应速度快的优点,最重要的是,对许多碱金属,碱土金属,过渡金属和重金属离子具有良好的选择性。在2.9-3.7的pH范围内,电极的电位响应与测试溶液的pH无关。电位滴定法测定得到的铀酰离子具有清晰的峰,具有稳定的基线,出色的重现性和极高的每小时170次进样的采样率。拟议的FIP系统用于测定真实和合成样品中的痕量铀酰离子。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号