Reusable Solid-Phase Microextraction Coating for Direct Immersion Whole-Blood Analysis and Extracted Blood Spot Sampling Coupled with Liquid Chromatography-Tandem Mass Spectrometry and Direct Analysis in Real Time-Tandem Mass Spectrometry

机译:可重复使用的固相微萃取涂层,用于直接浸没全血和液相色谱-串联质谱联用以及实时串联质谱直接分析中的提取血斑取样

获取原文
获取原文并翻译 | 示例
       

摘要

Three different biocompatible polymers were tested and evaluated in order to improve the whole-blood biocompatibility of previously developed C18-polyacrylonitrile (C18-PAN) thin-film solid-phase microextraction (SPME) coating. Among all methods of modification, UV-dried thin PAN-over C18-PAN provided the best results. This coating presented reusable properties and reproducible extraction efficiency for at least 30 direct extractions of diazepam from whole blood [relative standard deviation (RSD) = 12% using external calibration and 4% using isotope dilution calibration]. The amount of absolute recovery for direct immersion analysis and based on the free concentration of diazepam in blood matrix was about 4.8% (desorption efficiency = 98%). The limit of quantitation (LOQ) for the developed solid-phase microextraction liquid chromatography-tandem mass spectrometry (SPME-LC-MS/MS) method for direct whole-blood analysis was 0.5 ng/mL. The optimized modification of the coating was then used for an extracted blood spot (EBS) sampling approach, a new sampling method which is introduced to address the limitations of dried blood spot sampling. EBS was evaluated using LC-MS/MS and direct analysis in real time (DART)-MS/MS, where, for a 5 μL blood spot, LOQs of 0.2 and 1 μg/mL, respectively, were achieved for extraction of diazepam.
机译:测试和评估了三种不同的生物相容性聚合物,以改善先前开发的C18-聚丙烯腈(C18-PAN)薄膜固相微萃取(SPME)涂层的全血生物相容性。在所有修饰方法中,C18-PAN上的UV干燥薄PAN效果最佳。这种涂层具有从全血中至少30次直接提取地西presented的可重复使用的特性和可重复的提取效率[使用外部校准的相对标准偏差(RSD)= 12%,使用同位素稀释校准的4%]。直接浸入式分析的绝对恢复量是基于地西epa在血液基质中的自由浓度计,约为4.8%(解吸效率= 98%)。用于直接全血分析的已开发固相微萃取液相色谱-串联质谱(SPME-LC-MS / MS)方法的定量限(LOQ)为0.5 ng / mL。然后将涂层的优化改性用于提取血斑(EBS)采样方法,这是一种新的采样方法,旨在解决干血斑采样的局限性。使用LC-MS / MS和实时直接分析(DART)-MS / MS评估EBS,其中对于5μL血斑,提取地西LO的LOQ分别达到0.2和1μg/ mL。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号