首页> 外文期刊>Colloid and polymer science >Fluorescence study of the interaction between metal ions and methyl methacrylate methacrylic acid copolymers in aqueous solutions: thallium(I), calcium(II), and terbium(III)
【24h】

Fluorescence study of the interaction between metal ions and methyl methacrylate methacrylic acid copolymers in aqueous solutions: thallium(I), calcium(II), and terbium(III)

机译:(I),钙(II)和b(III)水溶液中金属离子与甲基丙烯酸甲酯/甲基丙烯酸共聚物的相互作用的荧光研究

获取原文
获取原文并翻译 | 示例
           

摘要

The binding of the cations thallium(I), calcium(II) and terbium(III) to methyl methacrylate-methacrylic acid copolymers with different fractions of acid groups (x) has been studied in aqueous solution at, various pH values using the fluorescence of covalently bonded 9-vinyl anthracene as a probe. In all cases, the extent of binding increases as a function of the charge of the polymer with either increasing fraction of carboxylic acids or of pH. However, differences are observed in the behavior of the three cations, With Tl(I), quenching of the anthracene group fluorescence is observed. indicating that the thallium(I) approaches the probe and suggesting that the alkylanthracene is probably in a relatively polar region. Binding constants have been determined from anthracene quenching data and from studies with the fluorescent-probe sodium pyrenetetrasulfonate, Good agreement is obtained between the two methods, and values for the binding constants increase from 250 to 950 M-1 as x increases from 0.39 to 1. It is suggested that the cation is held in the polyelectrolyte domain, partly by Debye-Huckel effects and partly by more specific interactions. Stronger binding is found with calcium(II) and terbium(III), and in this case increases in fluorescence intensity are observed on complexation due to the anthracene group being in a more hydrophobic region, probably as a result of conformational changes in the polymer chain. In the former case the stoichiometry of the interaction was determined from the fluorescence data to involve two carboxylate groups bound per calcium. Association constants were found using murexide as an indicator of free calcium to vary from 8400 to 37 000 M-1 as x increases from 0.39 to 1. It is suggested that in this case specific calcium(II)-carboxylate interactions contribute to the binding. With terbium(III), a greater increase in the probe fluorescence intensity was observed than with calcium, and it is suggested that the interaction with the polymer is even stronger, leading to a more pronounced conformational change in the polymer. It is proposed that the terbium(III) interacts with sis carboxylic groups on the polymer chain, with three being coordinated and three attracted by electrostatic interactions. [References: 40]
机译:阳离子th(I),钙(II)和ter(III)与具有不同比例的酸基(x)的甲基丙烯酸甲酯-甲基丙烯酸共聚物的结合已在水溶液中在各种pH值下使用共价键合的9-乙烯基蒽作为探针。在所有情况下,随着羧酸分数或pH值的增加,结合程度随聚合物电荷的增加而增加。然而,观察到三种阳离子的行为不同,利用Tl(I),观察到蒽基团荧光的猝灭。表明al(I)接近探针并表明烷基蒽可能处于相对极性的区域。从蒽淬灭数据和荧光探针pyr四磺酸钠的研究中确定了结合常数,两种方法之间获得了良好的一致性,并且随着x从0.39增至1,结合常数的值从250增至950 M-1。建议将阳离子保留在聚电解质域中,部分原因是通过Debye-Huckel效应,另一部分是通过更特定的相互作用。发现与钙(II)和b(III)的结合更牢固,在这种情况下,由于蒽基团位于更疏水的区域,可能是由于聚合物链构象变化的结果,在络合时观察到荧光强度增加。在前一种情况下,相互作用的化学计量由荧光数据确定,涉及每个钙结合的两个羧酸根。使用默立喜德作为游离钙的指示剂,发现缔合常数随x从0.39增至1而在8400至37 000 M-1之间变化。建议在这种情况下,特定的钙(II)-羧酸钙相互作用有助于结合。使用ter(III)时,观察到的探针荧光强度比使用钙时更大,并且表明与聚合物的相互作用甚至更强,导致聚合物中更明显的构象变化。提出the(III)与聚合物链上的sis羧基相互作用,其中三个被配位,三个被静电相互作用吸引。 [参考:40]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号