High cleaner air delivery rate performance of an two-stage ESP air cleaner for Indoor Air Quality with negligible ozone emission by carbon fiber ionizers

机译:两级ESP空气净化器具有较高的空气净化率,可改善室内空气质量,而碳纤维电离器的臭氧排放量可忽略不计

获取原文
获取原文并翻译 | 示例
       

摘要

A novel ESP type air cleaner with positive polarity was developed using an ionization stage with 16 carbon fiber ionizers in each channel, and a collection stage with parallel metallic plates. Its clean air delivery rate was measured by Korean standard test method using 0.3 μm KCl particles, changing applied voltages and flow rates of the air cleaner. The experimental results showed that its CADRs were changed from 7.9 to 12.1 m~3/min when applied voltage to ionizers (6 to 8 kV) and collection plates (-5 to -7 kV), and flow rate (10 to 20 m~3/min) were varied. In particular, the air cleaner achieved a CADR of 12.1 m~3/min with applied voltage of 8 kV to the ionization stage, and of - 6kV to the collection stage at 18 m~3/min, while emitting significant low ozone with a maximum value of 5.4 ppb for over 12 hours of continuous operation.
机译:开发了一种新型的具有正极性的ESP型空气净化器,该技术使用的是每个通道中有16个碳纤维离子发生器的电离级,以及具有平行金属板的收集级。通过韩国标准测试方法使用0.3μmKCl颗粒,改变施加的电压和空气滤清器的流量,测量其清洁空气的输送速度。实验结果表明,对电离器(6至8 kV)和收集板(-5至-7 kV)施加电压,流量(10至20 m〜)时,其CADR从7.9更改为12.1 m〜3 / min。 3 / min)。特别是,空气净化器的CADR为12.1 m〜3 / min,向电离级施加的电压为8 kV,向收集级施加的电压为18 m〜3 / min的电压为-6kV,同时排放的臭氧明显较低。连续运行12小时以上的最大值为5.4 ppb。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号