首页> 外文期刊>Clinical anatomy: official journal of the American Association of Clinical Anatomists & the British Association of Clinical Anatomists >Three-dimensional morphometrical analysis of the M1 segment of the middle cerebral artery: potential clinical and neurosurgical implications.
【24h】

Three-dimensional morphometrical analysis of the M1 segment of the middle cerebral artery: potential clinical and neurosurgical implications.

机译:大脑中动脉M1段的三维形态计量学分析:潜在的临床和神经外科意义。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

With an increase in the understanding of the formation and treatment of cerebral aneurysms and an improvement in imaging technology, actual standardized measurement values for the cerebral arteries are necessary. Therefore, the aim of this study was to provide a detailed assessment of the three-dimension (3D) morphology (vessel's curvature and trajectory) and 3D-morphometry of the M1 segment of the middle cerebral artery using computer tomography angiography (CTA) images. The DICOM files from CTA of 40 male and 75 female individuals with a mean age of 50.1 years were analyzed using an interactive postprocessing 3D volume-rendering algorithm. Specifically, the M1 segment was evaluated. Calculations included the length, internal diameter, volume, deviation (DI) and tortuosity indices (TI). The M1 segment had a mean internal diameter of 2.23 mm and was greater in men. M1 asymmetry was identified in 23.4% of the individuals and was more common in women. The mean length was 15.62 mm and the left M1 segments were a little longer. The mean volume of the M1 segments was 63.92 mm(3) , and this was typically greater in men and on the left sides. The mean TI and DI for the M1 segment were 0.91 and 2.17 mm, respectively. Therefore, the M1 segments are only slightly curved or straight in their course. In addition, the longest vascular M1 segments are more deviated (curved) and more tortuous. Such standardized data as presented herein may be useful in the preprocedural evaluation of patients with intracranial vascular pathology of the M1 segment.
机译:随着对脑动脉瘤的形成和治疗的理解的增加以及成像技术的改进,需要用于脑动脉的实际标准化测量值。因此,本研究的目的是使用计算机断层造影血管造影(CTA)图像,对大脑中动脉M1段的三维(3D)形态(血管的曲率和轨迹)和3D形态进行详细评估。使用交互式后处理3D体积渲染算法分析了平均年龄为50.1岁的40位男性和75位女性的CTA的DICOM文件。具体地,评估了M1区段。计算包括长度,内径,体积,偏差(DI)和曲折指数(TI)。 M1节段的平均内径为2.23毫米,男性较大。在23.4%的人群中发现M1不对称,在女性中更为常见。平均长度为15.62毫米,左侧M1段稍长。 M1段的平均体积为63.92 mm(3),在男性和左侧通常更大。 M1段的平均TI和DI分别为0.91和2.17 mm。因此,M1线段在其行程中仅略微弯曲或笔直。此外,最长的血管M1节段更偏斜(弯曲)且更弯曲。如本文所述的这种标准化数据可在具有M1节段的颅内血管病理的患者的术前评估中有用。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号