In this paper, we investigate an equivalent circuit for estimating connector contact failure, which saves computation resource significantly. The simulation results, validated by measurement, reveal that both the asymmetric contact distribution and fewer contact points increase the inductance on the connector. Using this lumped element circuit, different cable contact scenarios at the connection, i.e. the contact distribution and the number of contact points, can be simply simulated by changing the inductance term in the model.
机译:在本文中,我们研究了用于估计连接器接触故障的等效电路,从而显着节省了计算资源。通过测量验证的仿真结果表明,不对称的触点分布和更少的触点会增加连接器上的电感。使用该集总元件电路,可以通过更改模型中的电感项来简单地模拟连接处的不同电缆接触情况,即接触分布和接触点数量。