Screening as a method for determining the serum level of nitric oxide metabolites

机译:筛选作为确定一氧化氮代谢产物血清水平的方法

获取原文
获取原文并翻译 | 示例
           

摘要

The paper describes a modified method for determining stable nitric oxide (NO) metabolites, which permits one-stage assay of total nitrates and nitrites after blood serum deproteinization. The assay is based on the simultaneous reduction of nitrates and nitrites by vanadium chloride and by diazotization with subsequent stimulation of tinting whose rate is spectrophotometrically estimated at 540 nm. Assay of 100 microl of the deproteinized serum is made, by using a flat-bottomed 96-well plate. The sensitivity of the method is 1.7 microM. The concentration of total NO metabolites detected by the assay in the sera of volunteers ranged from 37.2 to 87.2 microM. It is suggested that the above modified assay may be used in clinical practice for the measurement of the concentrations of terminal NO metabolites since they are early markers of vascular endothelial NO-forming dysfunction.
机译:本文介绍了一种用于测定稳定的一氧化氮(NO)代谢物的改进方法,该方法允许对血清中的脱蛋白后的总硝酸盐和亚硝酸盐进行一阶段测定。该测定基于氯化钒同时重氮化和重氮化以及随后的着色刺激,该着色的速率通过分光光度法估计在540 nm处。使用平底96孔板测定100微升的脱蛋白血清。该方法的灵敏度为1.7 microM。通过该测定在志愿者血清中检测到的总NO代谢物浓度范围为37.2至87.2 microM。建议上述改进的测定法可在临床实践中用于测量末端NO代谢物的浓度,因为它们是血管内皮NO形成功能障碍的早期标志。