BACKGROUND: Newborn screening for congenital adrenal hyperplasia (CAH) is commonly accomplished by measurement of 17-alpha-hydroxyprogestrone (17-OHP) using enzyme immunoassay (EIA). EIA contributes a significant number of false positives. Therefore, second-tier steroid profile by liquid chromatography-tandem mass spectrometry (LC-MS/MS) is warranted. METHODS: Dried blood spots (DBS) were extracted with a mixture of methanol and water containing the deuterium labeled internal standards of d(8)-17-OHP, d(7)-androstenedione, and d(4)-cortisol. The final extracts were analyzed for 17-OHP, androstenedione and cortisol by LC-MS/MS in the multiple reaction monitoring (MRM) mode. RESULTS: Mean recoveries of the target analytes, 17-OHP, androstenedione and cortisol, were between 97 and 115% with an average intra- and inter-assay CVs ranging from 3.9-9.9% to 3.6-10.1%, respectively. The high efficiency of this method enabled us to test 11,598 specimens, identified as indeterminate by EIA in ~6 years; resulting in 809 presumptive positives reducing the false positives rate by 93%. CONCLUSIONS: The three steroid profile provided better screening outcomes of CAH than 17-OHP concentration alone. Our sample preparation allowed high throughput using common laboratory chemicals. Using three internal standards significantly improved method precision and accuracy. The reduction in false positives significantly reduces anxiety for newborns and their families.
机译:背景:先天性肾上腺皮质增生(CAH)的新生儿筛查通常是通过使用酶免疫法(EIA)测量17-α-羟基孕酮(17-OHP)来完成的。 EIA会导致大量误报。因此,通过液相色谱-串联质谱(LC-MS / MS)进行的二级类固醇分析是必要的。方法:用甲醇和水的混合物提取干血斑(DBS),其中含有氘标记的内标d(8)-17-OHP,d(7)-雄烯二酮和d(4)-皮质醇。通过LC-MS / MS在多反应监测(MRM)模式下分析最终提取物中的17-OHP,雄烯二酮和皮质醇。结果:目标分析物17-OHP,雄烯二酮和皮质醇的平均回收率在97%至115%之间,平均批内和批间CV值分别为3.9-9.9%至3.6-10.1%。这种方法的高效率使我们能够在11年内测试11598个标本,这些标本被EIA确定为不确定。导致809个假定阳性,从而使假阳性率降低了93%。结论:三种类固醇激素谱提供的CAH筛查结果优于单独的17-OHP浓度。我们的样品制备使用常规的实验室化学品即可实现高通量。使用三个内标大大提高了方法的准确性和准确性。假阳性的减少显着减少了新生儿及其家人的焦虑。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号