首页> 外文期刊>Clinical and experimental ophthalmology >Effect of scan repetition on the reproducibility of optic nerve head topographic measurements with the Top SS.
【24h】

Effect of scan repetition on the reproducibility of optic nerve head topographic measurements with the Top SS.

机译:扫描重复对使用Top SS进行的视神经乳头地形图测量的可重复性的影响。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Abstract Purpose: To determine the effect of scan repetition during a single visit for improved reproducibility of optic nerve head topographic measurements. Methods: One randomly selected eye of 20 healthy subjects with no systemic or ocular disease was evaluated. Half of the subjects were under 30 years of age and the other half were older than 60 years. Five independent image series, each consisting of 10 newly recorded consecutive images, were obtained for each subject over a period of 10 weeks with a confocal scanning laser ophthalmoscope, the Top SS. Subjects were divided into two groups according to disc area being either smaller or larger than 2 mm(2). Reproducibility of the measurements in three parameters (volume below, half depth area and the average depth) were calculated for each set of scans. The coefficient of variation (standard deviation divided by the mean) was taken as the measure of reproducibility. Repeated measures of analysis of variation and independent sample t-test were used for statistical analysis. Statistical significance was set as P < 0.05. Results: Both age groups were found to be equally distributed with respect to sex. There were no significant intergroup differences in keratometry, pupil diameter or refractive error. Increasing the scan repetition per visit up to five improved the reproducibility of the measurements. Further increases in scans per visit reduced the reproducibility. Subjects with larger discs and older age were found to have lower coefficients of variation for topographic measurements. Conclusions: Normal subjects should be examined at least three to four times per visit to have significantly improved reliability of measurements of optic nerve head topography. Factors associated with decreased reproducibility included older age, smaller discs, and more than five scans per visit. Sex, refraction and pupil diameter were shown to have no effect on the reproducibility.
机译:摘要目的:确定单次就诊时扫描重复的效果,以提高视神经乳头地形图测量的可重复性。方法:对20名健康的没有系统性或眼部疾病的健康受试者随机选择一只眼睛。一半的受试者年龄在30岁以下,另一半年龄超过60岁。使用共聚焦扫描激光检眼镜,Top SS,在10周内为每个受试者获得了五个独立的图像系列,每个图像系列由10个新记录的连续图像组成。根据椎间盘面积小于或大于2 mm(2)将受试者分为两组。对于每组扫描,计算了三个参数(低于体积,一半深度的区域和平均深度)的测量结果的可重复性。变异系数(标准偏差除以平均值)被用作再现性的度量。重复使用变异分析和独立样本t检验进行统计分析。统计学显着性设定为P <0.05。结果:发现两个年龄段的性别均等。角膜曲率,瞳孔直径或屈光不正之间没有显着的组间差异。将每次访问的扫描重复次数增加到最多五次,可以提高测量的可重复性。每次访问扫描次数的进一步增加会降低可重复性。发现具有较大椎间盘和较大年龄的受试者的地形测量变异系数较低。结论:正常受试者每次访视至少应检查3至4次,以显着提高视神经乳头地形图测量的可靠性。与再现性降低相关的因素包括年龄较大,光盘较小以及每次访问超过五次扫描。性别,屈光度和瞳孔直径对再现性没有影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号