...
首页> 外文期刊>Clinical and experimental ophthalmology >Relationship between macular ganglion cell complex thickness and macular outer retinal thickness: A spectral-domain optical coherence tomography study
【24h】

Relationship between macular ganglion cell complex thickness and macular outer retinal thickness: A spectral-domain optical coherence tomography study

机译:黄斑神经节细胞复合体厚度与黄斑外视网膜厚度之间的关系:光谱域光学相干断层扫描研究。

获取原文
获取原文并翻译 | 示例

摘要

Background: To assess the relationship between macular ganglion cell complex and macular outer retinal thicknesses. Design: Case-control study. Participants: Forty-two normal eyes and 91 eyes with primary open-angle glaucoma were studied. Methods: Spectral-domain optical coherence tomography (RTVue-100) was used to measure the macular ganglion cell complex and macular outer retinal thickness. Ganglion cell complex to outer retinal thickness ratio was also calculated. Main Outcome Measures: The relationships between the ganglion cell complex and outer retinal thicknesses and between the ganglion cell complex to outer retinal thickness ratio and outer retinal thickness were evaluated. Results: There was a positive correlation between ganglion cell complex and outer retinal thicknesses in the normal group and the glaucoma group (r=0.53, P<0.001 and r=0.42, P<0.001, respectively). In that respect, there was no correlation between ganglion cell complex to outer retinal thickness ratio and outer retinal thickness in the both groups (r=-0.07, P=0.657, and r=0.04, P=0.677, respectively). The ganglion cell complex to outer retinal thickness ratio was 55.65% in the normal group, 45.07% in the glaucoma group. This difference was statistically significant. Conclusions: The ganglion cell complex thickness may be affected by outer retinal thickness, and there is individual variation in the outer retinal thickness. Therefore, when determining the ganglion cell complex, it seems necessary to consider the outer retinal thickness as well. We propose the ratio as a suitable parameter to account for individual variations in outer retinal thickness.
机译:背景:评估黄斑神经节细胞复合物和黄斑外视网膜厚度之间的关系。设计:病例对照研究。参加者:研究了42只正常眼和91只原发性开角型青光眼。方法:使用光谱域光学相干断层扫描(RTVue-100)测量黄斑神经节细胞复合物和黄斑视网膜外层厚度。还计算了神经节细胞复合物与视网膜外膜的厚度比。主要观察指标:评估神经节细胞复合物与视网膜外膜厚度之间的关系,以及神经节细胞复合物与视网膜外膜厚度比和视网膜外膜厚度之间的关系。结果:正常组和青光眼组神经节细胞复合物与视网膜外层厚度呈正相关(r = 0.53,P <0.001,r = 0.42,P <0.001)。在这方面,两组神经节细胞复合物与视网膜外层厚度之比与视网膜外层厚度之间无相关性(分别为r = -0.07,P = 0.657,r = 0.04,P = 0.677)。正常组的神经节细胞复合物与视网膜外层厚度之比为55.65%,青光眼组为45.07%。这种差异具有统计学意义。结论:神经节细胞复合体的厚度可能受视网膜外层厚度的影响,并且视网膜外层厚度存在个体差异。因此,在确定神经节细胞复合物时,似乎也必须考虑视网膜的外部厚度。我们提出将比率作为合适的参数来解决视网膜外层厚度的个体变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号