首页> 外文期刊>Bioresource Technology: Biomass, Bioenergy, Biowastes, Conversion Technologies, Biotransformations, Production Technologies >Feasibility of a two-stage biological aerated filter for depth processing of electroplating-wastewater
【24h】

Feasibility of a two-stage biological aerated filter for depth processing of electroplating-wastewater

机译:两级曝气生物滤池用于电镀废水深度处理的可行性

获取原文
获取原文并翻译 | 示例
       

摘要

A "two-stage biological aerated filter" (T-SBAF) consisting of two columns in series was developed to treat electroplating-wastewater. Due to the low BOD/CODcr values of electroplating-wastewater, "twice start-up" was employed to reduce the time for adaptation of microorganisms, a process that takes up of 20 days. Under steady-state conditions, the removal of CODcr and NH4+ - N increased first and then decreased while the hydraulic loadings increased from 0.75 to 1.5 m(3) m(-2) h(-1). The air/water ratio had the same influence on the removal of CODcr and NH4+ - N when increasing from 3:1 to 6:1. When the hydraulic loadings and air/water ratio were 1.20 m(3) m(-2) h(-1) and 4:1, the optimal removal of CCDcr, NH4+ - N and total-nitrogen (T-N) were 90.13%, 92.51% and 55.46%, respectively. The effluent steadily reached the wastewater reuse standard. Compared to the traditional BAF, the period before backwashing of the T-SBAF could be extended to 10 days, and the recovery time was considerably shortened.
机译:开发了由两列串联组成的“两级曝气生物滤池”(T-SBAF),用于处理电镀废水。由于电镀废水的BOD / CODcr值较低,因此采用“两次启动”来减少适应微生物的时间,该过程需要20天。在稳态条件下,CODcr和NH4 +-N的去除先增加然后减少,而水力负荷从0.75增加到1.5 m(3)m(-2)h(-1)。当空气比从3:1增加到6:1时,对CODcr和NH4 +-N的去除具有相同的影响。当水力负荷和空气/水比为1.20 m(3)m(-2)h(-1)和4:1时,CCDcr,NH4 +-N和总氮(TN)的最佳去除率为90.13%,分别为92.51%和55.46%。出水稳定达到废水回用标准。与传统的BAF相比,T-SBAF的反洗前时间可以延长到10天,并且恢复时间大大缩短。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号