BACKGROUND: Microvascular anastomoses must be constructed perfectly in order to be successful. One of the subtle technical errors that can occur during construction is twisting of the anastomosis. In the present study, we examined the effect of twist on the immediate, 2-h postoperative angiographic dimensions and patency of microvascular anastomoses. MATERIALS AND METHODS: Sixty-four Sprague-Dawley rats were assigned randomly to four groups. The femoral arteries were dissected for a distance sufficient to permit the application of an 8.5-mm-long microanastomotic approximator clamp. Microarteriorrhaphies were performed with twists of 0 degrees, 90 degrees, 180 degrees, or 270 degrees. Patency was assessed 2 h after surgery using transabdominal aortic arteriography with run-off. Measurements were recorded for each anastomosis, as well as for the narrowest and widest diameters of the vessels within 10 mm of the anastomosis. RESULTS: Fifty-nine of the 64 rats had technically satisfactory angiograms which permitted measurement of vascular dimensions. The cross-sectional areas of the narrowest areas and the anastomoses were inversely related to the degree of twist, and were significantly reduced at 270 degrees (P < 0.05). Two-hour patency rates were 86% with 0 degrees twist, 82% with 90 degrees twist, 71% with 180 degrees twist, and 33% with 270 degrees twist. The reduction in patency with 270 degrees twist was statistically significant (P < 0.05). CONCLUSIONS: Twists of 0 degrees, 90 degrees, and 180 degrees did not impair patency at a statistically significant level, but twists of 270 degrees did significantly reduce patency of microvascular anastomoses (P < 0.05). Copyright 1998 Academic Press.
机译:背景:微血管吻合术必须完美构造才能成功。在施工过程中可能发生的细微技术错误之一是吻合术的扭曲。在本研究中,我们检查了扭曲对术后2小时血管造影尺寸和微血管吻合口通畅性的影响。材料与方法:64只Sprague-Dawley大鼠随机分为四组。解剖股动脉的距离足以允许使用8.5毫米长的微解剖吻合器钳。进行0次,90度,180度或270度扭转时进行微关节炎。术后2 h使用腹主动脉造影和径流评估通畅性。记录每个吻合口以及吻合口10毫米内最窄和最宽血管直径的测量值。结果:64只大鼠中有59只具有令人满意的血管造影照片,可以测量血管尺寸。最窄区域和吻合口的横截面积与扭曲度成反比,在270度时显着减小(P <0.05)。 2小时通畅率分别为:0度扭曲时为86%,90度扭曲时为82%,180度扭曲时为71%,而270度扭曲时为33%。 270度扭转通畅性的降低具有统计学意义(P <0.05)。结论:0度,90度和180度的扭曲并没有在统计学上显着影响通畅性,但是270度的扭曲确实显着降低了微血管吻合的通畅性(P <0.05)。版权所有1998学术出版社。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号