首页> 外文期刊>Journal of X-ray science and technology >The application of automatic tube current modulation (ATCM) on image quality and radiation dose at abdominal computed tomography (CT): A phantom study
【24h】

The application of automatic tube current modulation (ATCM) on image quality and radiation dose at abdominal computed tomography (CT): A phantom study

机译:自动管电流调制(ATCM)在腹部计算机断层扫描(CT)上对图像质量和辐射剂量的应用:幻像研究

获取原文
获取原文并翻译 | 示例
           

摘要

Multi-phase spiral Computed tomography (CT) of abdomen has been widely used as an effective imaging modality to diagnose variety of diseases. As a result, the accumulated radiation exposure on the abdomen is substantially higher than other human organ regions. According to ALARA (as low as reasonably achievable) principle, how to control radiation dose without compromising imaging quality becomes a research topic of high interest. However, how to achieve dose optimization of the abdomen CT examinations in Chinese patients have not been fully investigated in previous studies. In this study, we develop an abdomen-equivalent tissue model made by well-known CTP579 auxiliary testing model and the real CT data acquired from 68 Chinese male subjects. Combining with catphan600, we simulated the visibility of low and high contrast objects at adult abdomen under variety of x-ray dose levels. Using the automatic tube current modulation (ATCM) technique, we reduced the total radiation dose and identified a proper noise index (NI) for Chinese patients to maintain low or high contrast detectability of abdominal CT image. Our numerical experiments showed that in the phantom study for Chinese patients, when a NI was set at 10, the radiation dose reduced by 34.3% with low contrast objects detectable, while setting NI at 14 the dose level decreased by 65.1% without change the detectability of high contrast targets. The subjective ratings from three radiologists also yielded high consistence with Kappa > 0.75. This study demonstrated the feasibility of performing the CT dose optimization studies through a unique phantom with the ATCM method.
机译:腹部多相螺旋计算机断层扫描(CT)已被广泛用作诊断各种疾病的有效成像方式。结果,在腹部上累积的辐射暴露显着高于其他人体器官区域。根据ALARA(尽可能合理地降低)原理,如何在不损害成像质量的情况下控制辐射剂量成为人们关注的研究课题。然而,在先前的研究中尚未充分研究如何实现中国患者腹部CT检查的剂量优化。在这项研究中,我们建立了由著名的CTP579辅助测试模型制成的腹部等效组织模型,并从68位中国男性受试者中获得了真实的CT数据。结合catphan600,我们在各种X射线剂量水平下模拟了成年腹部低对比度和高对比度物体的可见性。使用自动管电流调制(ATCM)技术,我们减少了总辐射剂量,并为中国患者确定了适当的噪声指数(NI),以维持腹部CT图像的低或高对比度可检测性。我们的数值实验表明,在针对中国患者的体模研究中,将NI设置为10时,在可检测到低对比度对象的情况下,辐射剂量降低了34.3%,而将NI设置为14时,剂量水平降低了65.1%,而不会改变可检测性高对比度目标。来自三位放射科医生的主观评分也产生了较高的一致性,Kappa> 0.75。这项研究证明了使用ATCM方法通过独特的模型进行CT剂量优化研究的可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号