首页> 外文期刊>Journal of orthodontics >Assessment of the accuracy of a three-dimensional imaging system for archiving dental study models.
【24h】

Assessment of the accuracy of a three-dimensional imaging system for archiving dental study models.

机译:评估用于存档牙科研究模型的三维成像系统的准确性。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVE: The use of stone and plaster study models is an integral part of any dental practice and is required for research. Storage of study models is problematic in terms of space and cost. Ayoub et al.(1) introduced a new technique based on the recent advances in stereophotogrammetry for archiving dental study models in a digital format. However, assessment of the accuracy of the generated three-dimensional (3D) models has not been carried out yet. It was the aim of this study to evaluate the accuracy of this technique. DESIGN: A comparative assessment between direct measurements of dental study models and measurements of computer generated 3D images of the same study models was performed. MATERIALS AND METHODS: Twenty-two dental study models stored at Glasgow Dental Hospital and School for the purposes of research were used in the study. The models were captured in three dimensions using a photostereometric technique and stored in digital format. MAIN OUTCOME MEASURES: Measurements were conducted directly on dental study models and on the computer generated 3D images using Euclidean Distance Matrix Analysis.(2) The difference between the two sets of measurements was statistically analysed using a two-sample t-test. RESULTS: The average difference between measurements of dental casts and 3D images was 0.27 mm. This difference was within the range of operator errors (0.10-0.48 mm) and was not statistically significant (P < 0.05). CONCLUSION: This study shows that it is possible to use 3D imaging to store dental study models for treatment monitoring and research with a satisfactory degree of accuracy.
机译:目的:使用石材和石膏研究模型是任何牙科实践必不可少的一部分,是研究所必需的。研究模型的存储在空间和成本方面存在问题。 Ayoub等人(1)根据立体摄影测量学的最新进展介绍了一种新技术,用于以数字格式存档牙科研究模型。但是,尚未对生成的三维(3D)模型的准确性进行评估。这项研究的目的是评估该技术的准确性。设计:在牙科研究模型的直接测量与相同研究模型的计算机生成的3D图像的测量之间进行了比较评估。材料与方法:本研究使用了格拉斯哥牙科医院和学校存储的22种牙科研究模型进行研究。使用光度测量技术从三个维度捕获模型并以数字格式存储。主要观察指标:采用欧氏距离矩阵分析法直接在牙科研究模型和计算机生成的3D图像上进行测量。(2)使用两次样本t检验对两组测量之间的差异进行统计学分析。结果:铸模和3D图像的测量之间的平均差为0.27 mm。该差异在操作者误差范围内(0.10-0.48 mm),并且在统计学上无统计学意义(P <0.05)。结论:这项研究表明,可以使用3D成像技术以令人满意的准确度存储牙齿研究模型以进行治疗监测和研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号