Introduction Historically, there has been no objective method of measuring the time required for radiologists to produce reports during normal work. We have created a technique for semi-automated measurement of radiologist reporting time, and through it produced a robust set of absolute time requirements and relative value units for consultant reporting of diagnostic examinations in our hospital. Methods A large sample of reporting times, recorded automatically by the Radiology Information System (COMRAD, Software Innovations, Christchurch, New Zealand) along with the description of each examination being reported, was placed in a database. Analysis was confined to diagnostic reporting by consultant radiologists. A spreadsheet was produced, listing the total number and the frequency of reporting times of each distinct examination. Outliers with exceptionally long report times (more than 10 min for plain radiography, 30 min for ultrasound, or 60 min for CT or MRI with some exceptions) were culled; this removed 9.5% of the total. Complex CTs requiring separate workstation time were assigned times by consensus. The median time for the remainder of each sample was the assigned absolute reporting time in minutes and seconds. Relative value units were calculated using the reporting time for a single view department chest X-ray of 1 min 38 s including verifying a report made using speech recognition software. Results A schedule of absolute and relative values, based on over 179 000 reports, forms Table 2 of this paper. Conclusions The technique provides a schedule of reporting times with reduced subjective input, which is more robust than existing systems for measuring reporting time.
机译:简介历史上,一直没有客观的方法来测量放射线医生在正常工作期间产生报告所需的时间。我们创建了一种用于放射科医生报告时间的半自动测量的技术,并通过它为我院的诊断检查顾问报告提供了一套可靠的绝对时间要求和相对价值单位。方法将大量的报告时间样本(由放射信息系统(COMRAD,软件创新公司,新西兰基督城)自动记录)以及所报告的每次检查的描述存储在数据库中。分析仅限于放射线顾问的诊断报告。生成了一个电子表格,列出了每次不同检查的总数和报告时间的频率。剔除报告时间过长的异常值(普通X射线检查超过10分钟,超声检查超过30分钟,CT或MRI检查超过60分钟,但有一些例外);这删除了总数的9.5%。需要协商一致的时间来分配需要单独工作站时间的复杂CT。每个样本其余部分的中值时间是分配的绝对报告时间(以分钟和秒为单位)。相对值单位是使用1分钟38秒的单视野部门X射线的报告时间计算的,包括验证使用语音识别软件做出的报告。结果基于超过179 000份报告的绝对和相对值一览表构成了本文的表2。结论该技术为报告时间安排提供了一个减少主观输入的时间表,这比现有的测量报告时间的系统更为强大。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号