首页> 外文期刊>Journal of Wind Engineering and Industrial Aerodynamics: The Journal of the International Association for Wind Engineering >Design wind loads for low-rise buildings: A critical review of wind load specifications for industrial buildings
【24h】

Design wind loads for low-rise buildings: A critical review of wind load specifications for industrial buildings

机译:低层建筑的设计风荷载:对工业建筑风荷载规范的严格审查

获取原文
获取原文并翻译 | 示例
       

摘要

From extensive wind tunnel tests on low-rise buildings with flat roofs, two wind load distributions have been identified to be decisive for the design of the steel frames. Based on these results, the Eurocode 1 introduces a novel alternative wind load distribution with a positive roof pressure. In many design-practical cases, most of the codes reviewed do not sufficiently cover this wind action and its effects, leading to a possible under-design of the cross-sections of up to 35%. The recent trend to lighter construction and non-linear design needs further investigations of possible resonant effects. First results indicate that dynamic effects may have some additional influence on the design.
机译:通过对具有平坦屋顶的低层建筑进行的广泛风洞测试,确定了两种风荷载分布对于钢框架的设计至关重要。基于这些结果,Eurocode 1引入了一种新颖的替代性风荷载分布,其屋顶压力为正值。在许多实际设计案例中,所审查的大多数规范并未充分涵盖这种风作用及其影响,从而导致横截面设计不足的可能性高达35%。更轻的结构和非线性设计的最新趋势需要进一步研究可能的共振效应。初步结果表明,动态效果可能会对设计产生其他影响。