SUMMARY: To evaluate and compare thin section CT scans (TSS) and minimum intensity projection images (MinIPs) in healthy individuals, 10 nonsmokers with normal pulmonary function tests were studied using ten 1-mm collimated, helically acquired TSS images after full inspiration and expiration at two anatomic levels. Ten-millimeter-thick MinIPs were generated from the helical scans. Two thoracic radiologists compared TSS and MinIPs for artifacts and air trapping. Hounsfield unit (HU) measurements of TSS and MinIPs were obtained. The lung parenchyma on MinIPs demonstrates a smooth anterior-to-posterior attenuation gradient, accentuated by expiration. Motion and beam-hardening artifacts on TSS images resulted in regions of high and low attenuation on MinIPs, respectively. Expiratory TSS and MinIPs demonstrated air trapping (n = 31/40; range, 0-25%; mean, 7.2%). In comparison with TSS, MinIPs improved the conspicuity of air trapping (n = 20) and appeared to detect more air trapping (n = 7). No statistical differences were found when comparing the mean HU values of TSS and MinIPs. MinIPs demonstrated a smooth anterior-to-posterior attenuation gradient. Compared with TSS, MinIPs improve the conspicuity of air trapping in healthy individuals. Therefore, expiratory MinIPs may be useful in detecting air trapping as a result of disease.
机译:摘要:为了评估和比较健康个体的薄层CT扫描(TSS)和最小强度投影图像(MinIPs),研究了10名肺功能测试正常的非吸烟者,在完全吸气和呼气后,使用了10张1-mm螺旋状准直,螺旋获取的TSS图像在两个解剖层次上。螺旋扫描产生了10毫米厚的MinIP。两名胸部放射科医生比较了TSS和MinIPs的伪影和空气滞留情况。获得了TSS和MinIP的Hounsfield单位(HU)测量值。 MinIPs上的肺实质显示出前后平滑的衰减梯度,随着呼气而加重。 TSS图像上的运动和波束硬化伪像分别导致MinIP上的高衰减区域和低衰减区域。呼气TSS和MinIPs表现出空气滞留(n = 31/40;范围:0-25%;平均值:7.2%)。与TSS相比,MinIPs改善了空气陷阱的显着性(n = 20),并且似乎可以检测到更多的空气陷阱(n = 7)。比较TSS和MinIP的平均HU值时,未发现统计差异。 MinIPs表现出前后平滑的衰减梯度。与TSS相比,MinIPs改善了健康个体中空气滞留的隐患。因此,呼气MinIP可能在检测疾病导致的空气滞留方面很有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号