首页> 外文期刊>Journal of trace elements in medicine and biology: Organ of the Society for Minerals and Trace Elements (GMS) >On-line preconcentration/determination of zinc from water, Biological and food samples using synthesized chelating resin and flame atomic absorption spectrometry
【24h】

On-line preconcentration/determination of zinc from water, Biological and food samples using synthesized chelating resin and flame atomic absorption spectrometry

机译:使用合成螯合树脂和火焰原子吸收光谱法对水,生物和食品样品中的锌进行在线预富集/测定

获取原文
获取原文并翻译 | 示例

摘要

An on-line flow injection pre-concentration-flame atomic absorption spectrometry method was developed to determine trace zinc in water (tap, dam, and well water), biological (hair and nail), and liver samples. As a solid phase extractant, a synthesized new chelating resin, poly(2-thiozylmethacrylamide-co-divinylbenzene-co-2-acrylamido-2-methyl-1-propane sulfonic acid) was used. The resin was characterized by Fourier transform infrared spectroscopy, elemental analysis, and surface area by nitrogen sorption. A pre-concentration factor of 40-fold for a sample volume of 12.6mL was obtained by using the time-based technique. The detection limit for the pre-concentration method was found to be 2.2μgL-1. The precision (as RSD,%) for 10 replicate determinations at the 0.04μgmL-1 Zn concentration was 1.2%. The calibration graph using the pre-concentration system for zinc was linear with a correlation coefficient of 0.998 in the concentration range from 0.005 to 0.05μgmL-1. The applicability and accuracy of the developed method were estimated by the analysis spiked water, biological, liver samples (83-105%), and also certified reference material TMDA-70 (fortified lake water) and SPS-WW1 Batch 111-Wastewater. The results were in agreement with the certified values.
机译:开发了一种在线流动注射预浓缩-火焰原子吸收光谱法,用于测定水(自来水,大坝和井水),生物(头发和指甲)和肝脏样品中的痕量锌。作为固相萃取剂,使用了合成的新型螯合树脂,聚(2-硫唑基甲基丙烯酰胺-共二乙烯基苯-共-2-丙烯酰胺基-2-甲基-1-丙烷磺酸)。通过傅里叶变换红外光谱,元素分析和通过氮吸附的表面积对树脂进行了表征。通过使用基于时间的技术,对于12.6mL的样品体积,获得了40倍的预浓缩系数。预浓缩方法的检出限为2.2μgL-1。在0.04μgmL-1Zn浓度下进行10次重复测定的精密度(以RSD为单位,%)为1.2%。在0.005至0.05μgmL-1的浓度范围内,使用锌预浓缩系统的校准图呈线性,相关系数为0.998。通过分析加标水,生物样本,肝脏样本(83-105%)以及经认证的参考物质TMDA-70(强化湖水)和SPS-WW1 Batch 111-废水,评估了所开发方法的适用性和准确性。结果与认证值一致。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号