首页> 外文期刊>Coke and chemistry >Diagnostics of the Heating System and Lining of Coke Ovens
【24h】

Diagnostics of the Heating System and Lining of Coke Ovens

机译:焦炉加热系统和衬板的诊断

获取原文
获取原文并翻译 | 示例
           

摘要

Problems arising in the reconstruction of coke battery 1 at Isfahan steel plant are considered. The construction of coke battery 1 (coke-oven capacity 27.3 m3) with a PVR-51 dust-free coke-discharge system and bottom heating-gas supply is described. The losses of unprocessed coke-oven gas are calculated after coke-battery startup and after the elimination of leaks at seams in the refractory lining. Introduction of a method of detecting leaks at lining seams in the coke-oven walls reduces the losses of unprocessed coke-oven gas from 1738.73 to 44.6 m~3/h.
机译:考虑了在伊斯法罕钢铁厂炼焦电池1的重建过程中出现的问题。描述了具有PVR-51无尘焦炭排放系统和底部加热气体供应的焦炭电池1(焦炉容量27.3 m3)的构造。在焦炭电池启动后以及消除耐火炉衬接缝处的泄漏后,计算未处理的焦炉煤气的损失。引入一种检测焦炉壁衬里接缝处泄漏的方法,将未处理的焦炉气损失从1738.73降低到44.6 m〜3 / h。