首页> 外文期刊>Journal of vascular and interventional radiology: JVIR >The Gunther Tulip retrievable filter: prolonged temporary filtration by repositioning within the inferior vena cava.
【24h】

The Gunther Tulip retrievable filter: prolonged temporary filtration by repositioning within the inferior vena cava.

机译:Gunther Tulip可回收过滤器:通过在下腔静脉内重新定位来延长临时过滤时间。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: To report experience with the retrievable Gunther Tulip filter (GTF) as a means of temporary caval filtration for the prevention of pulmonary embolism (PE) with use of a technique that prolongs filter dwell time beyond 14 days. MATERIALS AND METHODS: Eighty-eight GTFs were implanted in 87 patients. The GTFs were placed with the intention of retrieval in all patients within 14 days after initial implantation. In 23 of the 87 patients (26%), there was a need to prolong temporary caval filtration beyond the recommended period of 14 days. This was successfully achieved with use of percutaneous techniques from the right internal jugular vein whereby the filter was repositioned to a different location within the inferior vena cava (IVC) before definitive device removal. RESULTS: Of 88 GTFs implanted in 87 patients, 70 were successfully retrieved and 18 were left in place permanently. Forty-seven filters in 46 patients were removed after initial implantation with no need for percutaneous repositioning within the IVC to prolong dwell time (mean dwell time, 13 days). In the 23 patients who required repositioning of 23 GTFs within the IVC to prolong temporary caval filtration, the mean dwell time was 34.8 days; the mean number of repositioning procedures was 1.5, the mean time between repositioning procedures was 13.8 days, and the mean fluoroscopy time was 4.4 minutes in patients in whom filter retrieval was attempted. One patient underwent placement and subsequent removal of the GTF twice for perioperative prophylaxis against PE on two separate occasions. No filters were misplaced in an unintended location or tilted (>15 degrees ) in relation to the main caval axis after deployment. In one patient, a GTF became permanently fixed in the IVC 16 days after initial implantation and could not be removed percutaneously. Nine patients had mild or moderate-sized cervical hematomas. One patient had recurrent asymptomatic PE 2 months after filter insertion. CONCLUSION: Dwell times of 14 days can be achieved in most patients before device removal. Prolongation of the dwell time beyond 14 days can be safely and easily achieved by performing percutaneous repositioning of the device within the IVC via a jugular approach.
机译:目的:报告使用可回收的Gunther Tulip过滤器(GTF)作为临时空洞过滤的方法的经验,该方法采用了将过滤器停留时间延长至14天以上的技术来预防肺栓塞(PE)。材料与方法:87例患者植入了88个GTF。放置GTF的目的是在初始植入后14天内将所有患者取出。在87名患者中的23名(26%)中,有必要将临时的腔室滤过时间延长至建议的14天以上。这是通过使用右颈内静脉的经皮技术成功实现的,其中,在确定性移除器械之前,将滤器重新放置在下腔静脉(IVC)内的其他位置。结果:在87例患者中植入88枚GTF,成功治愈了70枚,永久保留了18枚。初次植入后,移除了46例患者中的47个滤器,而无需在IVC内进行经皮重新定位以延长保压时间(平均保压时间,13天)。在需要在IVC内重新定位23个GTF以延长临时的腔室滤过的23例患者中,平均停留时间为34.8天;尝试进行滤器取出的患者中,平均重定位程序数为1.5,重定位程序之间的平均时间为13.8天,透视检查的平均时间为4.4分钟。一名患者在两次单独的手术中两次放置并随后取出GTF进行围手术期预防PE。部署后,没有将过滤器放错位置或相对于主腔室轴线倾斜(> 15度)。在一名患者中,初始植入后16天,GTF在IVC中永久固定,无法经皮切除。 9例患者患有轻度或中型宫颈血肿。一名患者在滤器插入后2个月复发无症状PE。结论:大多数患者在取出器械之前可以达到14天的驻留时间。通过经颈静脉入路在IVC内对器械进行经皮重新定位,可以安全,轻松地将停留时间延长至14天以上。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号