首页> 外文期刊>Journal of voice: official journal of the Voice Foundation >Estimating subglottal pressure via airflow interruption with auditory masking.
【24h】

Estimating subglottal pressure via airflow interruption with auditory masking.

机译:通过气流遮断和听觉掩蔽来估计声门下压力。

获取原文
获取原文并翻译 | 示例
           

摘要

Current noninvasive measurement of subglottal pressure using airflow interruption often produces inconsistent results due to the elicitation of audio-laryngeal reflexes. Auditory feedback could be considered as a means of ensuring measurement accuracy and precision. The purpose of this study was to determine if auditory masking could be used with the airflow interruption system to improve intrasubject consistency. A prerecorded sample of subject phonation was played on a loop over headphones during the trials with auditory masking. This provided subjects with a target pitch and blocked out distracting ambient noise created by the airflow interrupter. Subglottal pressure was noninvasively measured using the airflow interruption system. Thirty subjects, divided into two equal groups, performed 10 trials without auditory masking and 10 trials with auditory masking. Group one performed the normal trials first, followed by the trials with auditory masking. Group two performed the auditory masking trials first, followed by the normal trials. Intrasubject consistency was improved by adding auditory masking, resulting in a decrease in average intrasubject standard deviation from 0.93+/-0.51 to 0.47+/-0.22 cm H(2)O (P < 0.001). Auditory masking can be used effectively to combat audio-laryngeal reflexes and aid subjects in maintaining constant glottal configuration and frequency, thereby increasing intrasubject consistency when measuring subglottal pressure. By considering auditory feedback, a more reliable method of measurement was developed. This method could be used by clinicians, as reliable, immediately available values of subglottal pressure are useful in evaluating laryngeal health and monitoring treatment progress.
机译:由于引起听觉-喉部反射,当前使用气流中断的声门下压力的非侵入性测量经常产生不一致的结果。听觉反馈可以被认为是确保测量准确性和准确性的一种手段。这项研究的目的是确定是否可以在气流中断系统中使用听觉掩蔽来改善受试者内部的一致性。在进行听觉掩盖试验的过程中,预先录制的主题发声样本在耳机上循环播放。这为受试者提供了目标音高,并阻止了气流中断器产生的分散环境噪声。使用气流中断系统无创地测量声门下压力。 30名受试者被分为两组,分别进行了10次无听觉掩盖的试验和10次有听觉掩盖的试验。第一组首先进行正常试验,然后进行听觉掩盖试验。第二组首先进行听觉掩盖试验,然后进行正常试验。受试者内部的一致性通过增加听觉掩蔽得到改善,导致受试者内部的平均标准偏差从0.93 +/- 0.51降至0.47 +/- 0.22 cm H(2)O(P <0.001)。听觉掩蔽可有效地对抗声喉反射,并帮助受试者保持恒定的声门配置和频率,从而在测量声门下压力时增加受试者内部的一致性。通过考虑听觉反馈,开发了一种更可靠的测量方法。临床医生可以使用此方法,因为可靠的,即时可用的声门下压力值可用于评估喉部健康状况和监测治疗进度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号