The degree of acceptability of swine blood values at increasing levels of hemolysis evaluated through visual inspection versus automated quantification

机译:通过目视检查与自动定量评价的溶血水平在增加的猪血中的猪血值的可接受程度

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The pronounced fragility that characterizes swine erythrocytes is likely to produce a variable degree of hemolysis during blood sampling, and the free hemoglobin may then unpredictably bias the quantification of several analytes. The aim of this study was to evaluate the degree of acceptability of values obtained for several biochemical parameters at different levels of hemolysis. Progressively increased degrees of physical hemolysis were induced in 3 aliquots of 30 nonhemolytic sera, and the relative effects on the test results were assessed. To define the level of hemolysis, we used both visual estimation (on a scale of 0 to 3+) and analytical assessment (hemolytic index) and identified the best analytical cutoff values for discriminating the visual levels of hemolysis. Hemolysis led to a variable and dose-dependent effect on the test results that was specific for each analyte tested. In mildly hemolyzed specimens, C-reactive protein, haptoglobin, 1-globulin, 2-globulin, 1-globulin, -globulin, sodium, calcium, and alkaline phosphatase were not significantly biased, whereas 2-globulin, albumin, urea, creatinine, glucose, total cholesterol, aspartate aminotransferase, alanine aminotransferase, gamma-glutamyl transferase, nonesterified fatty acids, bilirubin, phosphorus, magnesium, iron, zinc, copper, lipase, triglycerides, lactate dehydrogenase, unbound iron-binding capacity, and uric acid were significantly biased. Chloride and total protein were unbiased even in markedly hemolyzed samples. Analytical interference was hypothesized to be the main source of this bias, leading to a nonlinear trend that confirmed the difficulty in establishing reliable coefficients of correction for adjusting the test results.
机译:表征猪血红细胞的明显脆弱性可能会在血液采样过程中产生不同程度的溶血作用,然后游离血红蛋白可能会不可预测地使几种分析物的定量产生偏差。这项研究的目的是评估在不同溶血水平下从几个生化参数获得的值的可接受程度。在30个非溶血性血清的3个等分试样中诱导逐渐增加的物理溶血程度,并评估了其对测试结果的相对影响。为了定义溶血水平,我们同时使用了视觉估计(0到3+的等级)和分析评估(溶血指数),并确定了最佳的分析临界值以区分溶血的视觉水平。溶血作用对测试结果产生可变和剂量依赖性的影响,这对每种被测分析物都是特定的。在轻度溶血的标本中,C反应蛋白,触珠蛋白,1-球蛋白,2-球蛋白,1-球蛋白,-球蛋白,钠,钙和碱性磷酸酶没有明显偏倚,而2-球蛋白,白蛋白,尿素,肌酐,葡萄糖,总胆固醇,天冬氨酸转氨酶,丙氨酸转氨酶,γ-谷氨酰胺基转移酶,非酯化脂肪酸,胆红素,磷,镁,铁,锌,铜,脂肪酶,甘油三酸酯,乳酸脱氢酶,未结合的铁结合能力和尿酸显着有偏见。即使在明显溶血的样品中,氯化物和总蛋白也没有偏见。假设分析干扰是这种偏差的主要来源,导致出现了非线性趋势,从而证实了建立可靠的校正系数以调整测试结果的难度。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号