We present encouraging results obtained with an experimental apparatus based on coherent population trapping and aimed at detecting a biological (cardiac) magnetic field in a magnetically compensated but unshielded volume. The work includes magnetic-field and magnetic-field-gradient compensation and uses differential detection to cancel common mode magnetic noise. Synchronous data acquisition with a reference (electrocardiographic or pulse-oximetric) signal makes possible improvement of the signal-to-noise ratio in off-line averaging. The setup has the significant advantages of working at room temperature with a small-size head, and the possibility of fast adjustments of the de bias magnetic field, which makes the sensor suitable for detecting a biomagnetic signal at any orientation with respect to the axis of the head and in any position on the patient's chest, which is not the case with other kinds of magnetometers. (c) 2007 Optical Society of America.
机译:我们提出了基于相干人口陷阱的实验设备获得的令人鼓舞的结果,其目的是在磁补偿但未屏蔽的体积中检测生物(心脏)磁场。这项工作包括磁场补偿和磁场梯度补偿,并使用差分检测来消除共模磁噪声。与参考(心电图或脉搏血氧饱和度)信号的同步数据采集可以改善离线平均中的信噪比。该装置的显着优点是可以在室温下使用小型磁头进行工作,并且可以快速调节偏置磁场,这使得该传感器适合于检测相对于磁场轴任何方向的生物磁信号。头部和患者胸部的任何位置,其他类型的磁力计则不然。 (c)2007年美国眼镜学会。