首页> 外文期刊>Journal of the Optical Society of America, A. Optics, image science, and vision >Scheimpflug and high-resolution magnetic resonance imaging of the anterior segment: a comparative study
【24h】

Scheimpflug and high-resolution magnetic resonance imaging of the anterior segment: a comparative study

机译:前段的Scheimpflug和高分辨率磁共振成像:对比研究

获取原文
获取原文并翻译 | 示例
       

摘要

High-resolution imaging with a camera system built on the Scheimpflug principle has been used to characterize the geometry of the anterior segment of the adult human eye as a function of aging and accommodative state but is critically dependent on algorithms for correction of distortion. High-resolution magnetic resonance imaging (MRI), in contrast, provides lower-resolution information about the adult eye but is undistorted. To test the accuracy of the Scheimpflug correction methods used by Cook and Koretz [J. Opt. Soc. Am. A 15, 1473 (1998)]; [Appl. Opt. 30, 2088 (1991)], data on anterior chamber and segment lengths, as well as lens thickness and anterior and posterior curvatures, were compared with corresponding MRI data for adults aged 18-50 at 0 diopter accommodation. Excellent statistical agreement was found between the MRI and the Scheimpflug data sets with the exception of the posterior lens radius of curvature, which is less well defined than the other measurements in the Scheimpflug images. The considerable agreement between data obtained with MR and Scheimpflug imaging, two different yet complementary in vivo imaging techniques, validates the Scheimpflug correction algorithms of Cook and Koretz and suggests the capability of directly integrating information from both. A third, equivalent, data set obtained with a Scheimpflug-style camera system differs considerably from both Scheimpflug and MRI results in magnitude and age dependence, with negative implications for this alternative method and its correction procedures.
机译:使用基于Scheimpflug原理的摄像头系统进行的高分辨率成像已被用来表征成年人眼的前节的几何形状,该几何形状是衰老和适应性状态的函数,但在很大程度上取决于校正畸变的算法。相比之下,高分辨率磁共振成像(MRI)提供了有关成年眼睛的较低分辨率信息,但没有失真。为了检验Cook和Koretz使用的Scheimpflug校正方法的准确性[J.选择。 Soc。上午。第15号,第1473页(1998年)]; [应用选择。 30,2088(1991)],将屈光度为0的18-50岁成年人的前房和节段长度以及晶状体厚度以及前后弯曲度的数据与相应的MRI数据进行了比较。在MRI和Scheimpflug数据集之间发现了极佳的统计一致性,但后晶状体曲率半径除外,后者的清晰度低于Scheimpflug图像中的其他测量值。用两种不同但互补的体内成像技术MR和Scheimpflug成像获得的数据之间的相当大的一致性,验证了Cook和Koretz的Scheimpflug校正算法,并暗示了直接整合两者信息的能力。用Scheimpflug式相机系统获得的第三个等效数据集在大小和年龄方面与Scheimpflug和MRI结果大不相同,这对这种替代方法及其校正程序具有负面影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号