An effluent standard is becoming severe from a viewpoint of environmental conservation in recent years. Perceiving to reduce selenium (Se(Vi)) that it is said to be difficulty, the examination was conducted for removal of selenium in solution with the high concentration of chloride ions which made the removal more difficult. Moreover, the experiment was carried out to remove selenium and fluorine which behaved as anion. The results can be summarized as follows:1) SeO_3~(2-) (IV) ions could be removed easily even in the solution with the high concentration of chloride ions. In the case of SeO_4~(2-) (VI), it was needed to be reduced to SeO_3~(2-). The quantity of reducing agent for solution including much amount of chloride ions was required as much as thousand times of amount of SeO_4~(2-).2) FeSO_4 centre dot 7H_2O was desirable for a reducing agent for the solution of high chloride concentration. FeCl_3 was needed to decrease the concentration of Fe. Furthermore, Ca(OH)_2 was suited to adjust pH rather than NaOH. Ca(OH)_2 improved the efficiency of both filtration and removal of SeO_4~(2-).3) It was possible to remove fluorine by using H_3PO_4 and to remove selenium with FeSO_4 continuously. Furthermore, the reaction of both was carried out under the same condition, pH 10. Therefore, it was found that it is an easy processing method to control pH.
机译:从环境保护的观点来看,近年来废水标准变得严格。认为减少硒(Se(Vi))据说很困难,因此进行了检查,以去除高浓度氯离子溶液中的硒,这使去除更加困难。此外,进行了去除作为阴离子的硒和氟的实验。结果可归纳为:1)即使在氯离子浓度高的溶液中,SeO_3〜(2-)(IV)离子也很容易去除。在SeO_4〜(2-)(VI)的情况下,需要还原为SeO_3〜(2-)。含大量氯离子的溶液用还原剂的量是SeO_4〜(2-)的千倍。2.FeSO_4中心点7H_2O是高浓度氯化物溶液用的还原剂。需要FeCl_3来降低Fe的浓度。此外,Ca(OH)_2适合于调节pH而不是NaOH。 Ca(OH)_2提高了SeO_4〜(2-)的过滤和去除效率。3)可以使用H_3PO_4去除氟,并用FeSO_4连续去除硒。此外,两者的反应都是在相同的pH 10条件下进行的。因此,发现控制pH是容易的加工方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号