Bioresorbable materials for implants have become increasingly researched over the last years. The bone-implant-interfaces of three different implant materials, namely a new bioresorbable magnesium alloy, a new self-reinforced polymer implant and a conventional titanium alloy, were tested using various methods: push-out tests, SEM and EDX analyses as well as surface analyses based on stereoscopic 3D pictures were conducted. The fracture energy is proposed as a very significant reference value for characterizing the mechanical performance of a bone-implant system. By using a video-extensometer system instead of, as is commonly done, tracking the movement of the crosshead in the push-out tests, the accuracy of measurement could be increased.
机译:近年来,用于植入物的生物可吸收材料得到了越来越多的研究。使用多种方法测试了三种不同植入物材料的骨-植入物界面,即一种新的可生物吸收的镁合金,一种新的自增强聚合物植入物和一种常规的钛合金:推出试验,SEM和EDX分析以及进行了基于立体3D图片的表面分析。提出断裂能作为表征骨植入系统机械性能的非常重要的参考值。通过使用视频引伸计系统,而不是像通常那样在推出测试中跟踪十字头的运动,可以提高测量的准确性。