Evaluation of the Response of the Modulation Transfer Function to a Computed Radiography Photostimulable Phosphor Imaging Plate for Various Numbers of X-ray Exposures

机译:各种数量的X射线曝光对计算机射线照相光刺激性荧光成像板的调制传递函数响应的评估

获取原文
获取原文并翻译 | 示例

摘要

The purpose of this project was to analyze the modulation transfer function (MTF) responses to a computed radiography (CR) imaging plate (IP) for various numbers of X-ray exposures and to determine whether or not the MTF response may be used as an indicator of image quality degradation. A measurement facility, which complies with the IEC 62220-1 international standard, has been set up to determine the MTF for computed X-ray detetor systems. The international standard (IEC 62220-1) was demonstrated to allows accurate and reliable measurements of the MTF, and the standardized radiation quality RQA 5 was applied for the measurements. The MTF is the modulation transfer function of the detector. The MTF was obtained from the images that were exposed using an opaque tungsten edge test device (2-mm thick). The presampled MTFs were deduced from the acquired images by using fast Fourier transform analysis techniques, andthe results suggested that a processing with MATLAB could be used to compute the MTF with confidence. To determine this, an Agfa MD CR cassette containing the photostimulable phosphor (PSP) imaging plate (IP) was used to obtain the MTF curve after calculating the line spread function (LSF) curve by calculating and differentiating the edge spread function (ESF) from the edge image. The results of MTF measurements will be presented. No distinctive changes were observed in the 50% MTF, which showed images for numbers of exposures less than 20,000. Also, the 10% MTF maintained a fixed pattern without a change in the image quality. In contrast, the study showed an irregularly shaped deteriorated image quality for the 50% and the 10% MTFs for numbers of exposures 20,000. In conclusion, the results of this examination may be used as a baseline for evaluating an image quality system and the imaging characteristics by using MTF measurement.
机译:该项目的目的是针对各种X射线曝光量分析对计算机射线照相(CR)成像板(IP)的调制传递函数(MTF)响应,并确定是否可以将MTF响应用作诊断对象。图像质量下降的指标。已经建立了符合IEC 62220-1国际标准的测量设备,可以确定X射线检测器系统的MTF。事实证明,国际标准(IEC 62220-1)可以精确可靠地测量MTF,并且将标准化的辐射质量RQA 5应用于测量。 MTF是检测器的调制传递函数。从使用不透明的钨边测试设备(2毫米厚)曝光的图像中获得MTF。利用快速傅里叶变换分析技术从采集的图像中推导出了预采样的MTF,结果表明可以使用MATLAB的处理来可靠地计算MTF。为了确定这一点,使用包含光刺激性荧光粉(PSP)成像板(IP)的Agfa MD CR盒式磁带,通过计算边缘扩散函数(ESF)并将其与边缘图像。将显示MTF测量的结果。在50%MTF中未观察到明显变化,该图像显示的曝光次数小于20,000。同样,10%MTF保持固定模式,而图像质量没有变化。相反,研究表明,对于20,000次曝光,MTF分别为50%和10%时,图像质量会出现不规则形状的下降。总之,该检查的结果可以用作通过使用MTF测量评估图像质量系统和成像特性的基准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号