Radio frequency (RF) power is one of the most important quantities in RF metrology. This paper summarizes the basic concepts of RF power standard, power sensor and the direct comparison technique used for power calibration. The automated calibration system has been developed using Agilent VEE Pro, coaxial thermistor mount as RF power reference standard, power sensor along with the power meter and GPIB cables. The system performs the calibration of power sensor against the reference standard coaxial thermistor mount in terms of calibration factor (CF) using the direct comparison technique. The software provides a graphical user interface that provides the fastest path of measurement and data acquisition. The automated power sensor calibration system has been successfully tested with the measurement uncertainty up to ±2.0% in the frequency range of 100 MHz to 18 GHz.
机译:射频(RF)功率是RF计量中最重要的量之一。本文总结了射频功率标准,功率传感器以及用于功率校准的直接比较技术的基本概念。自动校准系统是使用Agilent VEE Pro,同轴热敏电阻安装座作为射频功率参考标准,功率传感器以及功率计和GPIB电缆开发的。系统使用直接比较技术根据校准系数(CF)相对于参考标准同轴热敏电阻安装座执行功率传感器的校准。该软件提供了图形用户界面,可提供最快的测量和数据采集路径。功率传感器自动校准系统已成功测试,在100 MHz至18 GHz频率范围内,测量不确定度高达±2.0%。