OBJECTIVE: Few non-invasive methods are available for studying trigeminal nociception in humans. The 'nociception specific' blink reflex (nBR) is elicited by a preferential stimulation of trigeminal nociceptive fibers and is highly sensitive to changes in trigeminal nociception. The aim of this study was to establish its optimal stimulation parameters.METHODS: The inter-individual variability of R2 responses (41 healthy subjects), symmetry of R2 responses after right vs. left sided stimulation (25 subjects), optimal stimulation parameters (3 groups, each 16 subjects) and re-test reliability over time (15 subjects) were studied.RESULTS: The nBR had a R2 response with a latency of 44.7+/-7.3ms, but no R1 response. The mean difference of R2 latencies (right vs. left sided stimulation) was 0.4+/-2.1(SD)ms, the mean ratio of the R2 response areas (RA) was 1.05+/-0.39 (SD). Thus, lateral differences of onset latencies greater than 4.6ms (0.4+4.2 (2SD)) or >1.83-fold (1.05+0.78 (2SD)) of RA can be assumed as outside of normal range. Long inter-block intervals of 7min minimized the cumulative habituation of R2 RAs to 23%, onset latencies remained constant. Re-test reliability over 4 weeks was high both for latencies (Crohnbach's alpha=0.85) and RAs (alpha=0.94).CONCLUSIONS: The nBR with the established stimulation parameters could be used for studying trigeminal nociception.
机译:目的:很少有非侵入性方法可用于研究人类三叉神经痛。 “伤害感受特定的”眨眼反射(nBR)是由三叉神经伤害性纤维的优先刺激引起的,并且对三叉神经伤害感受的变化高度敏感。研究方法是建立最佳刺激参数。方法:R2反应的个体间差异(41名健康受试者),左右刺激后R2反应的对称性(25位受试者),最佳刺激参数(3结果:nBR具有R2反应,潜伏期为44.7 +/- 7.3ms,但无R1反应。 R2潜伏期(右侧刺激与左侧刺激)的平均差为0.4 +/- 2.1(SD)ms,R2响应区域(RA)的平均比率为1.05 +/- 0.39(SD)。因此,RA发作潜伏期的侧向差异大于4.6ms(0.4 + 4.2(2SD))或> 1.83倍(1.05 + 0.78(2SD))可以认为超出正常范围。较长的7min的间隔时间间隔将R2 RA的累积适应性降至23%,起病潜伏期保持恒定。潜伏期(克罗恩巴赫α= 0.85)和RAs(α= 0.94)在4周内的复测可靠性均很高。结论:具有确定的刺激参数的nBR可用于研究三叉神经痛。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号