...
首页> 外文期刊>Journal of the American College of Surgeons >Assessment of the reliability of data collected for the Department of Veterans Affairs national surgical quality improvement program.
【24h】

Assessment of the reliability of data collected for the Department of Veterans Affairs national surgical quality improvement program.

机译:评估退伍军人事务部国家外科手术质量改善计划所收集数据的可靠性。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: The Office of the Medical Inspector of the Department of Veterans Affairs (VA) studied the reliability of data collected by the VA's National Surgical Quality Improvement Program (NSQIP). The study focused on case selection bias, accuracy of reports on patients who died, and interrater reliability measurements of patient risk variables and outcomes. STUDY DESIGN: Surgical data from a sample of 15 VA medical centers were analyzed. For case selection bias, reviewers applied NSQIP criteria to include or exclude 2,460 patients from the database, comparing their results with those of NSQIP staff. For accurate reporting of patients who died, reviewers compared Social Security numbers of 10,444 NSQIP records with those found in the VA Beneficiary Identification and Records Locator Subsystem, VA Patient Treatment Files, and Social Security Administration death files. For measurement of interrater reliability, reviewers reabstracted 59 variables in each of 550 patient medical records that also were recorded in the NSQIP database. RESULTS: On case selection bias, the reviewers agreed with NSQIP decisions on 2,418 (98%) of the 2,460 cases. Computer record matching identified 4 more deaths than the NSQIP total of 198, a difference of about 2%. For 52 of the categorical variables, agreement, uncorrected for chance, was 96%. For 48 of 52 categorical variables, kappas ranged from 0.61 to 1.0 (substantial to almost perfect agreement); none of the variables had kappas of less than 0.20 (slight to poor agreement). CONCLUSIONS: This sample of medical centers shows adherence to criteria in selecting cases for the NSQIP database, for reporting deaths, and for collecting patient risk variables.
机译:背景:退伍军人事务部(VA)的医学检查员办公室研究了VA的国家手术质量改善计划(NSQIP)收集的数据的可靠性。该研究的重点是病例选择偏倚,死亡患者报告的准确性以及患者风险变量和结果的可靠度测量。研究设计:分析了来自15个VA医疗中心样本的手术数据。对于病例选择偏倚,审阅者应用NSQIP标准将2460名患者纳入数据库或从数据库中排除,并将其结果与NSQIP工作人员进行比较。为了准确报告死亡患者,审阅者将10,444个NSQIP记录的社会安全号码与VA受益人身份和记录定位子系统,VA患者治疗档案和社会安全管理局死亡档案中的数字进行了比较。为了测量间的可靠性,审阅者在550个患者病历中重新提取了59个变量,这些变量也记录在NSQIP数据库中。结果:在病例选择偏见方面,审阅者同意NSQIP对2460例病例中的2418例(98%)的决定。计算机记录匹配确定的死亡人数比NSQIP的总数198多4例,相差约2%。对于52个分类变量,未经偶然校正的一致性为96%。对于52个类别变量中的48个,kappas范围从0.61到1.0(基本一致)。所有变量的卡帕值均不小于0.20(一致性差)。结论:该医疗中心样本显示出在选择NSQIP数据库病例,报告死亡病例以及收集患者风险变量方面符合标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号