首页> 外文期刊>Journal of the American College of Cardiology >Agreement of visual estimation of coronary artery calcium from low-dose CT attenuation correction scans in hybrid PET/CT and SPECT/CT with standard Agatston score.
【24h】

Agreement of visual estimation of coronary artery calcium from low-dose CT attenuation correction scans in hybrid PET/CT and SPECT/CT with standard Agatston score.

机译:混合PET / CT和SPECT / CT中的低剂量CT衰减校正扫描与标准Agatston评分在视觉上估算冠状动脉钙的一致性。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVES: We sought to evaluate the accuracy and reproducibility of visual estimation of coronary artery calcium (CAC) from computed tomography attenuation correction (CTAC) scans performed for hybrid positron emission tomography (PET)/computed tomography (CT) and single-photon emission computed tomography (SPECT)/CT myocardial perfusion imaging (MPI). BACKGROUND: At the time of MPI, hybrid systems obtain a low-dose, non-electrocardiogram (ECG)-gated CT scan that is used to perform attenuation correction. Utility of this CTAC scan in estimating actual CAC as measured by Agatston score (AS) on standard ECG-gated scans has not been previously studied. METHODS: A total of 492 patients, from 3 centers, receiving both MPI with CTAC and a standard CAC scan were studied. At each site, experienced readers blinded to AS reviewed CTAC images, visually estimating CAC on a 6-level scale: classifying patients as estimated AS of 0, 1 to 9, 10 to 99, 100 to 300, 400 to 999, or >/=1,000. Agreement between visually estimated coronary artery calcium (VECAC) on CTAC and AS, measured standardly and converted to the same scale, was evaluated, as was inter-reader agreement. RESULTS: Although CTAC images are low dose and nongated, a high degree of association was observed between VECAC and AS, with 63% of VECACs in the same category as the AS category and 93% within 1 category. Weighted kappa was 0.89 (95% confidence interval: 0.88 to 0.91, p < 0.0001). High weighted kappa statistics were observed for each site, scanner type, and sex. Readers reported identical scores in 65% of cases and scores within 1 category in 93%. CONCLUSIONS: CAC can be visually assessed from low-dose CTAC scans with high agreement with AS. CTAC scans should be routinely assessed for VECAC.
机译:目的:我们试图通过对混合正电子发射断层摄影(PET)/计算机断层摄影(CT)和计算出的单光子发射进行的计算机断层摄影衰减校正(CTAC)扫描,评估冠状动脉钙(CAC)视觉估算的准确性和可重复性断层扫描(SPECT)/ CT心肌灌注成像(MPI)。背景:在进行MPI时,混合动力系统获得低剂量,非心电图(ECG)门控CT扫描,该扫描用于执行衰减校正。以前尚未研究过此CTAC扫描在估计实际CAC(如通过标准ECG门控扫描通过Agatston评分(AS)测量)的实用性。方法:研究了来自3个中心的492例同时接受CTAC的MPI和标准CAC扫描的患者。在每个站点,经验丰富的读者对AS审查过的CTAC图像不了解,以6级级别从视觉上评估CAC:将患者的AS评估为0、1至9、10至99、100至300、400至999或> / = 1,000。评估了CTAC和AS上视觉估算的冠状动脉钙(VECAC)之间的一致性,进行了标准测量并转换为相同的比例,这与阅读者之间的一致性一样。结果:尽管CTAC图像是低剂量且没有门控,但在VECAC和AS之间观察到高度关联,其中63%的VECAC与AS类别相同,而93%属于1类。加权kappa为0.89(95%置信区间:0.88至0.91,p <0.0001)。每个站点,扫描仪类型和性别均观察到了高加权Kappa统计数据。读者报告称,在65%的案例中得分相同,而在93%的案例中得分相同。结论:可以从低剂量CTAC扫描中视觉评估CAC,并与AS高度一致。 CTAC扫描应常规评估VECAC。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号