首页> 外文期刊>Journal of the American College of Cardiology >Mechanical aortic valve replacement in young women planning on pregnancy: Maternal and fetal outcomes under low oral anticoagulation, a pilot observational study on a comprehensive pre-operative counseling protocol
【24h】

Mechanical aortic valve replacement in young women planning on pregnancy: Maternal and fetal outcomes under low oral anticoagulation, a pilot observational study on a comprehensive pre-operative counseling protocol

机译:计划怀孕的年轻女性的机械性主动脉瓣置换术:口服抗凝药低的情况下的母婴结局,一项全面的术前咨询方案的初步观察性研究

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives: This pilot prospective observational study aimed to evaluate the maternal and fetal outcomes of pregnancies under low-dose oral anticoagulation therapy after aortic mechanical replacement. Background: Need for valve replacement is still an issue for young women with native valve disease who are planning on future pregnancy. Choice of replacement device is a challenging clinical task. Methods: A comprehensive pre-operative counseling protocol to guide choice of replacement device was developed. The pre-operative anticoagulation trial to determine the warfarin daily dosage needed to reach target international normalized ratio (INR) represented the main stem of such protocol. Pregnancies on low-dose anticoagulation therapy (target INR: 1.5 to 2.5) were allowed in a highly selected subset of mechanical aortic valve recipients. Results: Twenty-two patients of 40 originally referred for native valve disease surgery requiring valve replacement, safely underwent the pre-operative anticoagulation challenge. No maternal or fetal complications were detected in 16 pregnancies under low oral anticoagulation. Patterns of warfarin daily dosage and induced INRs were characterized during pregnancy. Conclusions: In this small sample observational study, a pre-operative anticoagulation therapy trial helped young women scheduled for valve replacement to acquire complete information as to the choice of prosthetic device. In selected third-generation mechanical aortic prosthesis recipients, low-dose anticoagulation therapy seems safe and feasible for both mother and fetus. Further studies are needed to validate this approach.
机译:目的:这项前瞻性前瞻性观察研究旨在评估主动脉机械置换后低剂量口服抗凝治疗下孕妇的胎儿和胎儿结局。背景:对于计划未来怀孕的患有天然瓣膜疾病的年轻女性,仍然需要更换瓣膜。选择替换设备是一项具有挑战性的临床任务。方法:制定了全面的术前咨询方案,以指导更换设备的选择。术前抗凝试验确定华法林每日剂量以达到目标国际标准化比例(INR)是该方案的主要目的。在高度选择的机械主动脉瓣接受者中允许进行小剂量抗凝治疗(目标INR:1.5至2.5)。结果:22名最初进行自然瓣膜疾病手术的40名患者中有22名需要更换瓣膜,他们接受了术前抗凝治疗。在低口服抗凝剂的情况下,在16例怀孕中未发现母婴并发症。在妊娠期间对华法林日剂量和诱导的INRs的模式进行了表征。结论:在这个小样本的观察性研究中,一项术前抗凝治疗试验帮助计划进行瓣膜置换的年轻女性获得了有关修复装置选择的完整信息。在选定的第三代机械主动脉假体接受者中,低剂量抗凝治疗对于母亲和胎儿都似乎是安全可行的。需要进一步研究以验证这种方法。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号