首页> 外文期刊>Journal of Structural Engineering >Exterior beam-column joint seismic behavior study using different joint core details with mechanical anchorage under reversal loading
【24h】

Exterior beam-column joint seismic behavior study using different joint core details with mechanical anchorage under reversal loading

机译:反向荷载作用下采用机械锚固不同节间芯细节的梁柱外节点地震行为研究

获取原文
获取原文并翻译 | 示例
           

摘要

Generally the reinforced concrete structures in the high seismic prone zone, exterior beam - column joints are detailed with confinement and conventional 90° standard bent hooks for longitudinal beam reinforcement anchorages. This results in congestion of reinforcement in joint core. Also, the placement of reinforcement and concrete pouring during construction is difficult at site. An attempt has been made to study and evaluate the performance of beam-column joints with joint detailing as per ACI-352, ACI-318 and TS-456 along with confinement as per IS-13920 and without confinement. Apart from reducing congestion of reinforcement in joint core, significant improvement in seismic performance, strength, ductility, stiffness were observed while using mechanical anchorage (Headed bar) in combination with X-Cross bar plus U-bar joint reinforcement for higher seismic prone area. To assess the performances of these types of anchorages and joint details, six numbers of specimens were assembled into two groups, each having three specimens was tested under reversal loading. These experimental test results were evaluated and presented in this paper.
机译:通常,在高地震易发区的钢筋混凝土结构,外部梁-柱节点处均采用了约束和传统的90°标准弯钩,用于纵向梁钢筋锚固。这导致接头芯中钢筋的拥挤。而且,在施工期间难以在现场放置钢筋和混凝土。曾尝试按照ACI-352,ACI-318和TS-456进行接头细节研究和评估梁柱节点的性能,以及根据IS-13920进行限制,但不进行限制。除了减少接头核心钢筋的拥挤外,在结合使用机械锚固(Headed bar)(X形钢筋和U形钢筋接头)来提高易发地震区域时,还观察到了抗震性能,强度,延展性和刚度的显着改善。为了评估这些类型的锚固和接头细节的性能,将六个数量的样本组装成两组,每组三个样本都在反向载荷下进行了测试。对这些实验测试结果进行了评估,并在本文中进行了介绍。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号