首页> 外文期刊>Journal of strength and conditioning research >ELECTROMYOGRAPHIC AMPLITUDE VS. CONCENTRIC AND ECCENTRIC SQUAT FORCE RELATIONSHIPS FOR MONOARTICULAR AND BIARTICULAR THIGH MUSCLES
【24h】

ELECTROMYOGRAPHIC AMPLITUDE VS. CONCENTRIC AND ECCENTRIC SQUAT FORCE RELATIONSHIPS FOR MONOARTICULAR AND BIARTICULAR THIGH MUSCLES

机译:电泳放大器VS.单眼和双眼大肌肉的集中和偏心平方力关系

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Luera, MJ, Stock, MS, and Chappell, ADW. Electromyographic amplitude vs. concentric and eccentric squat force relationships for monoarticular and biarticular thigh muscles. J Strength Cond Res 28(2): 328-338, 2014This study examined the linearity of the electromyographic (EMG) amplitude vs. concentric and eccentric squat force relationships for monoarticular and biarticular thigh muscles. Fourteen resistance-trained men (mean age +/- SD: 22 +/- 2 years; estimated thigh muscle cross-sectional area: 221.9 +/- 22.7 cm(2)) performed concentric and eccentric squats using a novel testing device from 10 to 90% of their maximum average force. Surface EMG signals were detected from the right vastus lateralis, rectus femoris, and biceps femoris. Linear regression was used to examine the relationships between EMG amplitude and force, and repeated measures analyses of variance were used to assess differences among the muscles. Moderate-to-high coefficients of determination were found for the vastus lateralis for both concentric and eccentric testings (r(2) = 0.587-0.992). For the biceps femoris, the mean linear slope coefficient was significantly greater for concentric vs. eccentric testing (0.044 vs. 0.013 V RMSN-1; p = 0.002; effect size = 1.44). Although EMG amplitude for the vastus lateralis and rectus femoris increased with changes in eccentric force output, the electrical activity of the biceps femoris remained stable. These results demonstrated that the EMG amplitude vs. force relationships for the vastus lateralis were linear, despite the fact that force production during the squat is related to the activation of muscles that must simultaneously function as agonists and antagonists. Our findings for eccentric force testing are in agreement with investigations showing reduced hip extensor activity during concurrent extension at the hip and knee joints.
机译:密西根州的Luera,MS的Stock和ADW的Chappell。单关节和双关节大腿肌肉的肌电振幅与同心和偏心深蹲力的关系。 J Strength Cond Res 28(2):328-338,2014这项研究研究了单关节和双关节大腿肌肉的肌电图(EMG)振幅与同心和偏心深蹲力关系的线性。 14名接受过阻力训练的男人(平均年龄+/- SD:22 +/- 2岁;估计的大腿肌肉横截面积:221.9 +/- 22.7 cm(2))使用来自10岁的新型测试设备进行了同心和偏心深蹲达到其最大平均力量的90%。从右侧股外侧肌,股直肌和股二头肌检测到表面肌电信号。线性回归用于检查肌电图振幅和力量之间的关系,重复测量方差分析用于评估肌肉之间的差异。对于同心和偏心测试,均发现了股外侧肌的中度到高测定系数(r(2)= 0.587-0.992)。对于股二头肌,同心测试与偏心测试的平均线性斜率系数明显更高(0.044 vs. 0.013 V RMSN-1; p = 0.002;效果大小= 1.44)。尽管随着偏心力输出的变化,股外侧肌和股直肌的肌电图振幅增加,但股二头肌的电活动保持稳定。这些结果表明,尽管下蹲期间的力量产生与必须同时起激动剂和拮抗剂作用的肌肉的激活有关,但股外侧肌的EMG振幅与力量的关系是线性的。我们的偏心力测试结果与调查显示在髋关节和膝关节同时伸展时髋部伸肌活动减少的调查结果一致。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号