首页> 外文期刊>Journal of postgraduate medicine >Unusual way of loosened total hip arthroplasty treatment with an Austin Moore endoprosthesis
【24h】

Unusual way of loosened total hip arthroplasty treatment with an Austin Moore endoprosthesis

机译:用Austin Moore内修复物松动全髋关节置换术的不寻常方法

获取原文
获取原文并翻译 | 示例
       

摘要

A 65-year-old female patient with aseptic loosening of total cemented hip endoprosthesis and pathologic fracture of the femur at the level of the stem of endoprosthesis was presented. As no appropriate endoprosthesis was available due to the war in Croatia and war priority, the problem was managed by femur osteosynthesis and implantation of a partial Austin Moore hip endoprosthesis. The endoprosthesis is still functioning well (for 20 years).To the best of the author's knowledge, nobody has ever treated problem like this using this alternative, an unconventional method, with an Austin Moore endoprosthesis.
机译:介绍了一名65岁的女性患者,该患者全髋关节置换术无菌性松动,并且股骨在茎的水平处发生病理性骨折。由于在克罗地亚的战争和战争优先考虑下没有合适的内置假体,因此该问题通过股骨骨合成术和部分奥斯汀·摩尔髋关节内置假体的植入得以解决。内置假体仍然可以正常工作(长达20年)。据作者所知,没有人使用Austin Moore内置假体使用这种非常规方法来解决这种问题。