首页> 外文期刊>Journal of refractive surgery >Measurement of pupil center shift in refractive surgery candidates with Caucasian eyes using infrared pupillometry
【24h】

Measurement of pupil center shift in refractive surgery candidates with Caucasian eyes using infrared pupillometry

机译:使用红外瞳孔法测量高加索人屈光手术候选人的瞳孔中心偏移

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To evaluate the effectiveness of the pupil center shift with changes in the state of pupil size and with other ocular variables. METHODS: Dynamic pupillometry with the Topolyzer Vario (Alcon Laboratories, Inc., Fort Worth, TX) was performed in 248 eyes of 124 patients scheduled for corneal laser refractive surgery. High-resolution images were obtained using the infrared-sensitive camera (incorporated in the videokeratoscope) under mesopic and photopic conditions. Measurements of pupil diameters, distance between the pupil center and keratoscopic axis, and spatial shift of the pupil center were obtained after analysis. RESULTS: The mean distance between the pupil center and the corneal vertex in mesopic and photopic conditions of illumination in myopic eyes was 0.27 ± 0.14 (range: 0.02 to 0.70 mm) and 0.24 ± 0.12 mm (range: 0.06 to 0.65 mm), respectively, whereas it was 0.36 ± 0.15 (range: 0.03 to 0.70 mm) and 0.31 ± 0.16 mm (range: 0.03 to 0.77 mm) in hyperopic eyes, respectively. The mean spatial pupil center shift was significant: 0.11 ± 0.07 mm (range: 0.02 to 0.57 mm) in myopic eyes and 0.12 ± 0.09 mm (range: 0.02 to 0.47 mm) in hyperopic eyes. The pupil center shifted consistently temporally as the pupil dilated. The pupil center shift was not significantly related to sex, age, eye (right or left), or refractive error. CONCLUSIONS: The mean distance between the pupil center and the corneal vertex is greater in hyperopic eyes than in myopic eyes, whereas the spatial shift of this pupil center has a temporal direction as the pupil dilates and is constantly small in all groups. However, pupil center shift can be important in a few patients.
机译:目的:通过改变瞳孔大小状态和其他眼球变量来评估瞳孔中心偏移的有效性。方法:使用Topolyzer Vario(爱尔康实验室,公司,德克萨斯州沃思堡)的动态瞳孔测量法对计划进行角膜激光屈光手术的124例患者的248眼进行了检查。使用红外敏感相机(内置于视频角膜镜中)在中视和近视条件下获得高分辨率图像。分析后获得瞳孔直径,瞳孔中心与角膜镜轴之间的距离以及瞳孔中心的空间偏移的测量值。结果:在近视眼和近视眼照明条件下,瞳孔中心与角膜顶点之间的平均距离分别为0.27±0.14(范围:0.02至0.70 mm)和0.24±0.12 mm(范围:0.06至0.65 mm) ,而远视眼的分别为0.36±0.15(范围:0.03至0.70 mm)和0.31±0.16 mm(范围:0.03至0.77 mm)。平均空间瞳孔中心偏移很明显:近视眼为0.11±0.07 mm(范围:0.02至0.57 mm),远视眼为0.12±0.09 mm(范围:0.02至0.47 mm)。随着瞳孔扩大,瞳孔中心在时间上始终一致地移动。瞳孔中心偏移与性别,年龄,眼睛(右或左)或屈光不正无关。结论:远视眼的瞳孔中心和角膜顶点之间的平均距离大于近视眼,而该瞳孔中心的空间位移随着瞳孔的扩大而具有时间方向,并且在所有组中均较小。但是,在少数患者中,瞳孔中心偏移可能很重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号