首页> 外文期刊>Journal of refractive surgery >Comparison of immersion ultrasound, partial coherence interferometry, and low coherence reflectometry for ocular biometry in cataract patients.
【24h】

Comparison of immersion ultrasound, partial coherence interferometry, and low coherence reflectometry for ocular biometry in cataract patients.

机译:白内障患者眼部生物浸没超声,部分相干干涉法和低相干反射法的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To compare ocular biometry parameters measured with immersion ultrasound, partial coherence interferometry, and low coherence reflectometry in cataract patients. METHODS: Measurements of axial length and anterior chamber depth were analyzed and compared using immersion ultrasound, partial coherence interferometry, and low coherence reflectometry. Keratometry (K), flattest axis, and white-to-white measurements were compared between partial coherence interferometry and low coherence reflectometry. Seventy-eight cataract (LOCS II range: 1 to 3) eyes of 45 patients aged between 42 and 90 years were evaluated. A subanalysis as a function of cataract degree was done for axial length and anterior chamber depth between techniques. RESULTS: No statistically significant differences were noted for the study cohort or within each cataract degree among the three techniques for axial length and anterior chamber depth (P>.05, ANOVA test). Measurements between techniques were highly correlated for axial length (R=0.99) and anterior chamber depth (R=0.90 to 0.96) for all methods. Keratometry, flattest axis, and white-to-white measurements were comparable (paired t test, P>.1) and correlated well between partial coherence interferometry and low coherence reflectometry (K1 [R=0.95), K2 [R=0.97], flattest axis [R=0.95], and white-to-white [R=0.92]). CONCLUSIONS: Immersion ultrasound, partial coherence interferometry, and low coherence reflectometry provided comparable ocular biometry measurements in cataractous eyes.
机译:目的:比较在白内障患者中用浸入式超声,部分相干干涉法和低相干反射法测量的眼部生物学参数。方法:使用浸入式超声,部分相干干涉法和低相干反射法对轴向长度和前房深度的测量结果进行分析和比较。比较了部分相干干涉测量法和低相干反射测量法之间的角膜测量法(K),最平坦的轴和白色至白色的测量结果。评估了45例年龄在42至90岁之间的患者的78只白内障(LOCS II范围:1至3)。对于白内障度数的函数,对两种技术之间的轴向长度和前房深度进行了亚分析。结果:在研究的队列中或在每种白内障度内,三种技术在轴向长度和前房深度方面均无统计学差异(P> 0.05,ANOVA测试)。对于所有方法,技术之间的测量值均与轴向长度(R = 0.99)和前房深度(R = 0.90至0.96)高度相关。角膜测量法,最平坦的轴和白色至白色的测量值具有可比性(配对t检验,P> .1),并且在部分相干干涉法和低相干反射法之间具有很好的相关性(K1 [R = 0.95],K2 [R = 0.97],最平坦的轴[R = 0.95],以及白色至白色[R = 0.92])。结论:浸没超声,部分相干干涉测量法和低相干反射测量法可为白内障眼提供可比的眼部生物测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号