PURPOSE: To report refractive outcomes of laser in situ keratomileusis (LASIK) for myopia with and without astigmatism using the Nidek EC-5000 and Meditec Mel 70 excimer laser systems. METHODS: A retrospective analysis of refractive outcomes with each laser was conducted. Approximately 5700 eyes treated for myopia and myopic astigmatism were analyzed. Preoperative sphere ranged from -0.25 to -15.50 D and cylinder ranged from -0.75 to -5.50 D. All statistical analyses were performed by Datagraph med version 2.8 refractive analysis software. RESULTS: With the Nidek EC-5000 at 6 months after LASIK, mean spherical equivalent refraction was -0.24 D with 72% of eyes within +/- 0.50 D. In the Meditec cohort, the mean spherical equivalent was -0.54 D with 55% of eyes +/- 0.50 D. CONCLUSION: Eyes treated for myopia and astigmatism with either of these lasers showed early refractive stability and similar efficacy. Higher incidences of epithelial ingrowth and haze were present in the Meditec treated eyes.
机译:目的:报告使用Nidek EC-5000和Meditec Mel 70准分子激光系统对有或没有散光的近视眼原位角膜磨镶术(LASIK)的屈光结果。方法:对每台激光的屈光结果进行回顾性分析。分析了近视和近视散光治疗的约5700只眼睛。术前球的范围为-0.25至-15.50 D,圆柱体的范围为-0.75至-5.50D。所有统计分析均通过Datagraph med 2.8版屈光分析软件进行。结果:在LASIK手术后6个月使用Nidek EC-5000时,平均球面等效屈光度为-0.24 D,其中72%的眼睛在+/- 0.50 D以内。在Meditec队列中,平均球面等效屈光度为-0.54 D,其中55%眼数+/- 0.50D。结论:用这两种激光中的任何一种治疗近视和散光的眼睛均具有早期屈光稳定性和类似功效。 Meditec处理的眼睛中上皮向内生长和混浊的发生率较高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号