Repeatability of ocular response analyzer waveform parameters in normal eyes and eyes after refractive surgery

机译:眼反应分析仪波形参数在正常眼睛和屈光手术后眼睛中的可重复性

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To study the repeatability of the biomechanical waveform parameters measured with the Ocular Response Analyzer (Reichert Ophthalmic Instruments, Depew, NY) device in normal eyes and eyes after refractive surgery. METHODS: This was a prospective, comparative noninterventional study of a case series. Two hundred eyes of 100 patients were divided into five groups: normal eyes of patients younger than 30 years, normal eyes of patients between 30 and 50 years old, normal eyes of patients older than 50 years, eyes of patients with a history of LASIK, and eyes of patients with a history of photorefractive keratectomy. The repeatability of the 37 waveform parameters in addition to corneal hysteresis (CH), corneal resistance factor (CRF), IOP measurement with Goldmann applanation tonometer (IOPg), and IOP evaluated with the intraclass correlation coefficient (ICC) (IOPcc) were examined. RESULTS: In addition to IOPg, IOPcc, CRF, and CH, five parameters had an ICC greater than 0.6 (substantial agreement): P1area, the area of peak 1 (ICC = 0.823); P2area, the area of peak 2 (ICC = 0.646); h1, the height of peak 1 (ICC= 0.702); P1area1, the area of peak 1 derived from the upper 50% of the applanation peak (ICC = 0.772); and h11, the height of peak1 derived from the upper 50% of the applanation peak 1 (ICC = 0.697). CONCLUSIONS: This study shows that not all parameters derived from the corneal deformation waveform signal have the same repeatability. Therefore, analysis of the waveform indices should rely on the more repeatable ones to derive consistent conclusions.
机译:目的:研究用眼响应分析仪(Reichert Ophthalmic Instruments,Depew,NY)设备在正常眼睛和屈光手术后的眼睛中测量的生物力学波形参数的可重复性。方法:这是一个病例系列的前瞻性,比较性非干预性研究。 100名患者的200眼分为五组:30岁以下的患者的正常眼睛,30至50岁之间的患者的正常眼睛,50岁以上的患者的正常眼睛,有LASIK病史的患者的眼睛,有屈光性角膜切除术史的患者的眼睛和眼睛。除了角膜滞后(CH),角膜阻力因子(CRF),使用Goldmann压平眼压计(IOPg)进行的IOP测量以及使用组内相关系数(ICC)(IOPcc)评估的IOP之外,还检查了这37个波形参数的可重复性。结果:除了IOPg,IOPcc,CRF和CH,五个参数的ICC均大于0.6(基本一致):P1面积,峰1的面积(ICC = 0.823); P2面积,峰2的面积(ICC = 0.646); h1,峰1的高度(ICC = 0.702); P1area1,峰1的面积来自压平峰的上50%(ICC = 0.772); h11,峰1的高度来自压平峰1的高50%(ICC = 0.697)。结论:这项研究表明,并非所有来自角膜变形波形信号的参数都具有相同的可重复性。因此,波形指标的分析应依靠可重复性更高的指标来得出一致的结论。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号