首页> 外文期刊>Journal of refractive surgery >Measurement of LASIK flap thickness with anterior segment optical coherence tomography.
【24h】

Measurement of LASIK flap thickness with anterior segment optical coherence tomography.

机译:前段光学相干断层扫描测量LASIK皮瓣厚度。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: To assess the interobserver variability and agreement of anterior segment optical coherence tomography (OCT) in the measurement of LASIK flap thickness, and to compare the results with intraoperative ultrasound pachymetry measurements. METHODS: Thirty-nine eyes of 20 consecutive patients undergoing LASIK with the XP microkeratome (Bausch & Lomb) and ALLEGRETTO Eye-Q laser system (WaveLight Inc) had corneal flap thickness measured with SP-100 ultrasound (Tomey Corp) intraoperatively and with OCT (Visante; Carl Zeiss Meditec Inc) postoperatively. Interobserver assessment was performed by comparing the flap thickness measurements obtained from the same scan by 2 masked, independent observers. Agreement of OCT scan was determined by assessment of 2 different scans of the same eye by the same observer. RESULTS: Mean (+/- standard deviation) flap thickness measured by ultrasound, OCT scan 1 (OCT 1-1) and scan 2 (OCT 1-2) assessed by observer 1, and OCT scan 1 (OCT 2-1) and scan 2 (OCT 2-2) assessed by observer 2 were 112.79+/-19.71, 124.69+/-17.02, 127.59+/-17.32, 130.59+/-20.34, and 133.74+/-19.70 microm, respectively. No statistically significant difference among the interobserver measurements was seen. The difference between OCT and ultrasound measurements by observers 1 and 2 was statistically significant (P<.01). Correlation among all measurements was statistically significant. Good agreement among the OCT scans was noted. CONCLUSIONS: Optical coherence tomography showed good correlation among measurements and observers for different OCT measurements in the assessment of corneal flap thickness after LASIK. However, OCT significantly overestimated flap thickness when compared to ultrasound despite a good correlation between these two modalities. Optical coherence tomography measurements should not be substituted for standad ultrasound measurements at the present time.
机译:目的:评估前段光学相干断层扫描(OCT)的观察者间差异和一致性,以测量LASIK皮瓣厚度,并将结果与​​术中超声测厚法进行比较。方法:连续20例使用XP微型角膜刀(Bausch&Lomb)和ALLEGRETTO Eye-Q激光系统(WaveLight Inc)进行LASIK手术的患者的三十九只眼,在术中和OCT情况下采用SP-100超声(Tomey Corp)测量角膜瓣厚度。 (Visante;卡尔·蔡司Meditec Inc)术后。观察者之间的评估是通过比较由两名戴面具的独立观察者从同一次扫描中获得的皮瓣厚度测量值来进行的。通过由同一位观察者对同一只眼睛进行两次不同的扫描评估,可以确定OCT扫描的一致性。结果:通过超声,OCT扫描1(OCT 1-1)和扫描2(OCT 1-2),观察者1进行评估,OCT扫描1(OCT 2-1)和通过超声测量的平均(+/-标准偏差)皮瓣厚度观察者2评估的第二次扫描2(OCT 2-2)分别为112.79 +/- 19.71、124.69 +/- 17.02、127.59 +/- 17.32、130.59 +/- 20.34和133.74 +/- 19.70微米。观察者之间的测量之间没有统计学上的显着差异。观察者1和2进行的OCT和超声测量之间的差异具有统计学意义(P <.01)。所有测量之间的相关性具有统计学意义。有人指出,OCT扫描之间有很好的一致性。结论:光学相干断层扫描显示在不同的OCT测量结果与LASIK术后角膜瓣厚度评估之间,测量值和观察者之间具有良好的相关性。然而,尽管这两种方式之间具有良好的相关性,但与超声相比,OCT仍显着高估了皮瓣厚度。目前,光学相干断层扫描测量不能替代标准超声测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号