首页> 外文期刊>Journal of refractive surgery >Ocular rigidity evaluation after photorefractive keratectomy: an experimental study.
【24h】

Ocular rigidity evaluation after photorefractive keratectomy: an experimental study.

机译:屈光性角膜切除术后的眼球硬度评估:一项实验研究。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: To evaluate possible changes of the ocular rigidity coefficient in vivo after photorefractive keratectomy (PRK) in a series of rabbit eyes, using an invasive ocular rigidity measurement device. METHODS: Sixteen eyes of 8 rabbits were used in this study. One eye from each rabbit underwent PRK for -10.00 diopters (D) in a 5-mm optical zone (92 microm) while the fellow eye served as the control. Five weeks later, the rabbits were examined under general anesthesia. The pressure-volume relationship and the ocular rigidity coefficient were determined in all 16 eyes, by injecting 200 microL of saline solution (in increments of 4.5 microL) through the limbus into the anterior chamber, while the intraocular pressure (IOP) was continually monitored with a transducer, up to a maximum limit of 40 mmHg. Data within an IOP range of 10 to 40 mmHg were used to calculate the ocular rigidity coefficient. RESULTS: The preoperative central corneal thickness was comparable (P = .73, paired t test) in the pre-PRK eyes (mean: 347.5 +/- 17.11 microm) and control eyes (mean: 349.1 +/- 17.46 microm). No statistically significant difference was noted in measured ocular rigidity coefficient between eyes treated with PRK and control eyes (mean rigidity coefficient: 0.42 +/- 0.12 mmHg/microL [range: 0.23 to 0.56] and 0.47 +/- 0.12 mmHg/microL [range: 0.28 to 0.62], respectively, with 95% confidence interval of the difference, lower: -0.10 to upper: 0.015, P = .121). CONCLUSIONS: Photorefractive keratectomy did not significantly alter ocular rigidity measurements in this experimental model.
机译:目的:使用侵入性眼刚度测量装置,评估一系列兔眼光折射性角膜切除术(PRK)后体内眼刚度系数的可能变化。方法:本研究使用了8只兔子的16只眼。每只兔子的一只眼睛在5毫米光学区域(92微米)内接受PRK -10.00屈光度(D),另一只眼睛作为对照。五周后,在全身麻醉下检查兔子。通过将200 microL盐溶液(以4.5 microL的增量)通过角膜缘缘注入前房,测定所有16只眼的压力-体积关系和眼刚度系数,同时连续监测眼压(IOP)。传感器,最大限制为40 mmHg。 IOP范围在10到40 mmHg之间的数据用于计算眼部刚度系数。结果:PRK前眼(平均:347.5 +/- 17.11微米)和对照眼(平均:349.1 +/- 17.46微米)的术前中央角膜厚度相当(P = 0.73,配对t检验)。经PRK治疗的眼睛和对照组眼睛之间的眼刚度系数在统计学上无显着差异(平均刚度系数:0.42 +/- 0.12 mmHg / microL [范围:0.23至0.56]和0.47 +/- 0.12 mmHg / microL [范围:分别为0.28至0.62],差异的置信区间为95%,下限:-0.10至上限:0.015,P = .121)。结论:在该实验模型中,光折射性角膜切除术并未显着改变眼球硬度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号