首页> 外文期刊>Journal of refractive surgery >Wavefront-guided LASIK for myopia using the LADAR CustomCornea and the VISX CustomVue.
【24h】

Wavefront-guided LASIK for myopia using the LADAR CustomCornea and the VISX CustomVue.

机译:使用LADAR CustomCornea和VISX CustomVue的波前引导LASIK用于近视。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To evaluate the objective and subjective visual outcomes and refractive results of wavefront-guided LASIK with LADAR CustomCornea and VISX CustomVue. METHODS: This prospective randomized single-institution multisurgeon study comprised 100 eyes of 58 patients (50 eyes on each laser platform). Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), and manifest refraction were measured postoperatively at 1 day, 1 week, 1 month, and 3 months. Contrast sensitivity, higher order aberrations measurement, and a subjective vision questionnaire were performed preoperatively and at 3 months. RESULTS: Preoperatively, the CustomCornea group had a mean manifest sphere of -3.58 +/- 1.61 diopters (D) (range: -0.50 to -7.25 D), cylinder of +0.64 +/- 0.45 D (range: 0 to +1.75 D), and manifest refractive spherical equivalent (MRSE) of -3.26 +/- 1.56 D. The CustomVue group had a manifest sphere of -4.00 +/- 1.69 D (range: -1.50 to -7.50 D), cylinder of +0.60 +/- 0.52 D (range: 0 to +2.00 D), and MRSE of -3.70 +/- 1.64 D. At 3 months, 94% of CustomCornea eyes and 84% of CustomVue eyes had UCVA > or = 20/20 (P = .20). Twenty-four percent of CustomVue eyes and 22% of CustomCornea eyes gained 1 line of BSCVA. In both groups, 96% of eyes were within 0.50 D of emmetropia. Mean CustomCornea glare contrast sensitivity improved (P = .04) whereas more eyes improved than worsened in both groups. Spherical aberration and total higher order aberrations increased, and trefoil decreased in both groups. A decrease in coma was noted in 70% of CustomCornea eyes. CONCLUSIONS: Wavefront-guided LASIK with both platforms is safe, effective, and delivers excellent visual results. CustomCornea improves contrast sensitivity under glare conditions.
机译:目的:使用LADAR CustomCornea和VISX CustomVue评估波前引导LASIK的客观和主观视觉结果以及屈光结果。方法:这项前瞻性随机单机构多手术研究包括58例患者的100眼(每个激光平台50眼)。术后1天,1周,1个月和3个月测量未矫正视力(UCVA),最佳眼镜矫正视力(BSCVA)和明显屈光度。术前和术后3个月进行了对比敏感性,高阶像差测量和主观视觉问卷调查。结果:术前CustomCornea组的平均明显球面度为-3.58 +/- 1.61屈光度(D)(范围:-0.50至-7.25 D),圆柱度为+0.64 +/- 0.45 D(范围:0至+1.75 D),并且明显的球面等效屈光度(MRSE)为-3.26 +/- 1.56D。CustomVue组的明显球面为-4.00 +/- 1.69 D(范围:-1.50至-7.50 D),圆柱度为+0.60 +/- 0.52 D(范围:0至+2.00 D),MRSE为-3.70 +/- 1.64 D.在3个月时,94%的CustomCornea眼和84%的CustomVue眼的UCVA>或= 20/20( P = 0.20)。 24%的CustomVue眼睛和22%的CustomCornea眼睛获得1条BSCVA。两组中,有96%的眼睛处于正视眼0.50 D以内。两组的平均CustomCornea眩光对比敏感度均得到改善(P = .04),而改善的眼睛多于恶化的眼睛。两组的球差和总高阶像差增加,三叶形减少。在70%的CustomCornea眼睛中发现昏迷有所减少。结论:两个平台的波前引导LASIK安全,有效,并提供出色的视觉效果。 CustomCornea可提高眩光条件下的对比度灵敏度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号