首页> 外文期刊>Journal of refractive surgery >Monochromatic aberrations in eyes with different intraocular lens optic designs.
【24h】

Monochromatic aberrations in eyes with different intraocular lens optic designs.

机译:具有不同眼内透镜光学设计的眼睛中的单色像差。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To study the wavefront aberration profile of eyes with three different types of intraocular lenses (IOLs)--the Tecnis Z9000 (modified prolate surface design) (Pfizer, New York, NY), the Acrysof MA60BM (unequal biconvex optic) (Alcon, Ft Worth, Tex), and the Sensar Optiedge AR40e (equibiconvex optic) (AMO, Santa Ana, Calif)--in eyes following cataract surgery. METHODS: This study was conducted in two parts. The first part was a randomized open study of 32 eyes of 16 patients who underwent bilateral phacoemulsification with a foldable IOL in the capsular bag. A Tecnis Z9000 IOL was implanted in one eye and an Acrysof MA60BM IOL in the fellow eye. The ALLEGRETTO WAVE Analyzer (Wavelight Laser Technologies AG, Erlangen, Germany) was used to measure ocular aberrations 2 weeks after surgery. A paired t test was used to compare each Zernike term from Z3(-3) to Z6(6) between fellow eyes (pupil diameter = 6 mm). In the second part of the study, the wavefront aberrations of 16 eyes that underwent an identical surgical procedure as in the first part of the study but had a Sensar Optiedge AR40e IOL implanted were studied and compared with eyes with the Tecnis Z9000 and Acrysof MA60BM IOLs. RESULTS: The mean spherical aberration (Z4(0)) was statistically significantly lower in eyes with a Tecnis Z9000 IOL (Z4(0) = 0.07 +/- 0.12 microm) compared with eyes with an Acrysof MA60BM IOL (Z4(0) = 0.29 +/- 0.20 microm, P < .001) and with eyes with a Sensar Optiedge AR40e IOL (Z4(0) = 0.20 +/- 0.09 microm, P = .002). No statistically significant differences were noted in any of the Zernike terms between eyes with Acrysof MA60BM and Sensar Optiedge AR40e IOLs, or in the root-mean-square (RMS) of total higher order aberrations among the three IOL groups. CONCLUSIONS: The implantation of a Tecnis Z9000 IOL produces a significant reduction in spherical aberration of the eye. No significant differences were noted in the wavefront profile between eyes with Acrysof MA60BM and Sensar Optiedge AR40e IOLs. No significant differences were found in the RMS of total higher order aberrations among the three IOL groups.
机译:目的:研究使用三种不同类型的人工晶状体(IOL)的眼睛的波前像差轮廓-Tecnis Z9000(改良的扁长表面设计)(Pfizer,纽约,纽约),Acrysof MA60BM(不等的双凸光学镜)(Alcon ,Ft Worth,Tex)和Sensar Optiedge AR40e(等轴凸光学镜)(AMO,加利福尼亚州圣安娜)在白内障手术后的眼睛中。方法:本研究分为两个部分。第一部分是对16例患者的32眼进行随机开放研究,这些患者在囊袋中进行了可折叠IOL的双侧超声乳化术。将Tecnis Z9000 IOL植入一只眼睛,将Acrysof MA60BM IOL植入另一只眼睛。手术后2周,使用ALLEGRETTO WAVE分析仪(Wavelight Laser Technologies AG,​​德国埃尔兰根)测量眼像差。配对t检验用于比较另一只眼睛(瞳孔直径= 6 mm)中从Z3(-3)到Z6(6)的每个Zernike项。在研究的第二部分中,研究了与研究第一部分相同的手术程序但植入了Sensar Optiedge AR40e IOL的16只眼睛的波前像差,并将其与Tecnis Z9000和Acrysof MA60BM IOL的眼睛进行了比较。 。结果:与使用Acrysof MA60BM IOL(Z4(0)=)的眼睛相比,Tecnis Z9000 IOL(Z4(0)= 0.07 +/- 0.12 microm)的眼睛的平均球差(Z4(0))在统计学上显着降低0.29 +/- 0.20微米,P <0.001)和使用Sensar Optiedge AR40e IOL(Z4(0)= 0.20 +/- 0.09微米,P = .002)的眼睛。使用Acrysof MA60BM和Sensar Optiedge AR40e IOL的眼睛之间的任何Zernike术语,或三个IOL组之间的总高阶像差的均方根(RMS),都没有发现统计学上的显着差异。结论:植入Tecnis Z9000 IOL可显着降低眼睛的球差。使用Acrysof MA60BM和Sensar Optiedge AR40e IOL的眼睛之间的波前轮廓没有显着差异。三个IOL组之间的总高阶像差RMS均未发现显着差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号