The effects of acetate and nitrate as pushing agents on the high-performance anion-exchange chromatography with pulsed amperometric detector (HPAEC-PAD) for the separation and detection of debranched amylopectin were evaluated. Our experimental data indicated that nitrate could differentiate branched from linear isomers, whereas acetate could not. Therefore, the nitrate system had better separating power than the acetate system provided that the chromatograms under both gradient systems were completed within 100 min. Nitrate was more compatible with the detector than acetate; thus, a higher detector response resulted. Under our experimental conditions, with a signal-to-noise ratio of two, the number of DP (degree of polymerization) at various concentrations that was resolved by the nitrate system (62 at 0.5 mg/mL, 65 at 1.0 mg/mL, and 66 at 1.5 mg/mL) was larger than those resolved by the acetate system (56 at 0.5 mg/mL, 58 at 1.0 mg/mL, and 58 at 1.5 mg/mL). The chromatograms obtained from the nitrate gradient system were more reproducible than those from the acetate gradient system in terms of the consistencies of retention time and the peak area of the chromatographic peak. To various concentrations of the component with the same DP, the detector responses were more consistent with nitrate as a pushing agent compared with acetate. Neither pushing agent, however, resulted in a quantitative response for homologous debranched amylopectin.
机译:评估了乙酸盐和硝酸盐作为促进剂对高效阴离子交换色谱仪(用于分离和检测脱支支链淀粉)的脉冲安培检测器(HPAEC-PAD)的影响。我们的实验数据表明硝酸盐可以区分直链异构体的支链,而乙酸盐则不能。因此,如果两个梯度系统下的色谱图均在100分钟内完成,则硝酸盐系统的分离力比乙酸盐系统更好。硝酸盐比乙酸盐与检测器的相容性更好。因此,产生了更高的检测器响应。在我们的实验条件下,信噪比为2时,硝酸盐系统解析的各种浓度下的DP(聚合度)数(0.5 mg / mL时为62,1.0 mg / mL时为65,和在1.5 mg / mL时的66)大于通过醋酸盐系统分辨的那些(在0.5 mg / mL时为56,在1.0 mg / mL时为58,在1.5 mg / mL时为58)。就保留时间和色谱峰的峰面积的一致性而言,从硝酸盐梯度系统获得的色谱图比从乙酸盐梯度系统获得的色谱图更具重现性。对于具有相同DP的各种浓度的组分,与硝酸盐作为推动剂相比,检测器响应与硝酸盐更为一致。但是,两种推动剂均未导致同源脱支支链淀粉的定量反应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号