首页> 外文期刊>Journal of prosthodontics: official journal of the American College of Prosthodontists >The effects of abutment taper, length and cement type on resistance to dislodgement of cement-retained, implant-supported restorations.
【24h】

The effects of abutment taper, length and cement type on resistance to dislodgement of cement-retained, implant-supported restorations.

机译:基台锥度,长度和水泥类型对水泥固位,种植体支撑的修复体抗脱位性的影响。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: The purpose of this study was to compare the effect of 20 degrees and 30 degrees of total occlusal convergence (TOC), the occlusocervical dimension, and the type of cement on the tensile resistance to dislodgement of cement-retained, implant-supported restorations. MATERIALS AND METHODS: Cylindrical preparations with TOC angles of 20 degrees and 30 degrees and occlusocervical dimensions of 4 mm (S) and 8 mm (L) were made through a machining process. The cylinders had a shoulder finish line of 1.0 mm in depth. Eight impressions were made of each machined cylinder and poured in type IV dental stone, for a total of 32 dies. Die spacer was applied to each die. A master wax pattern was designed, and the 32 wax patterns were marginated, invested, and cast in type IV gold alloy (n = 8). The gold crowns were cemented with Fleck's cement (zinc phosphate cement), Temp-Bond (zinc oxide eugenol cement), Temp-Bond plus Vaseline (30% by weight), and IMProv temporary cement (acrylic/urethane cement) under a 10-kg load and placed in a humidor at 37 degrees C for 1 hour before testing. A uniaxial tensile force was applied to the crown using an Instron machine with a crosshead speed of 5 mm/min until cement failure occurred. Analysis of variance models were fit to determine the effect of TOC, occlusocervical dimension, and cement type of the restorations on the mean tensile strength. RESULTS: For each type of cement, the mean tensile strengths were significantly higher at 20 degrees of TOC and 8 mm of occlusocervical dimension compared with the other preparations. At this preparation, IMProv had the highest mean tensile resistance to dislodgement (47.7 +/- 8.4 kg), followed by Fleck's (38.2 +/- 8.8 kg), Temp-Bond (35.9 +/- 4.4 kg), and Temp-Bond plus Vaseline (8.2 +/- 2.2 kg). No statistically significant difference was observed between Temp-Bond and Fleck's zinc phosphate cement when 20 degrees of TOC and 8 mm of occlusocervical dimension was used. There was no statistical difference in the mean tensile resistanceto dislodgement for Temp-Bond plus Vaseline with different preparation designs (p > 0.05) except when 20 degrees of TOC and 8 mm of occlusocervical dimension was used. The mean tensile strength was significantly different between Temp-Bond and Temp-Bond plus Vaseline for each of the 4 preparation designs (p < 0.05). Among the cements tested, IMProv exhibited higher values, which were statistically different (p < 0.05). Restorations with greater occlusocervical dimension and less TOC exhibited higher tensile resistance to dislodgement. CONCLUSIONS: Preparations with 20 degrees of TOC and 8 mm of occlusocervical dimension had significantly higher mean retentive values for all of the cements tested. Significant differences in mean tensile strength were observed, with the highest tensile resistance seen with IMProv, followed by Fleck's cement, and the lowest tensile resistance seen with Temp-Bond plus Vaseline.
机译:目的:本研究的目的是比较20度和30度总咬合会聚(TOC),咬合颈尺寸和水泥类型对保留在种植体支撑的种植体上的抗拉强度的影响。材料与方法:通过机加工工艺制成TOC角为20度和30度,咬合口尺寸为4毫米(S)和8毫米(L)的圆柱形制剂。圆柱体的肩部终点线深度为1.0毫米。每个机械加工的圆柱体均产生8个压痕,并倒入IV型牙石中,总共32个模具。模具间隔件被施加到每个模具。设计了一个主蜡模,对32个蜡模进行了边缘处理,进行了喷漆并铸造成IV型金合金(n = 8)。金冠用10摄氏度以下的水泥用Fleck的水泥(磷酸锌水泥),Temp-Bond(氧化锌丁香酚水泥),Temp-Bond加凡士林(30%重量)和IMProv临时水泥(丙烯酸/聚氨酯水泥)粘接在进行测试前,先将其装入200千克的容器中,并在37摄氏度的雪茄盒中放置1小时。使用Instron机器以5 mm / min的十字头速度将单轴拉伸力施加到胎冠,直到发生水泥破坏。方差分析模型适合确定TOC,咬合子宫颈尺寸和​​修复体的水泥类型对平均抗拉强度的影响。结果:对于每种类型的水泥,与其他制剂相比,在20°C的TOC和8 mm的咬合颈尺寸时,平均抗拉强度明显更高。在此准备过程中,IMProv的平均抗拉性最高(47.7 +/- 8.4 kg),其次是Fleck(38.2 +/- 8.8 kg),Temp-Bond(35.9 +/- 4.4 kg)和Temp-Bond加上凡士林(8.2 +/- 2.2公斤)。当使用20度TOC和8 mm的咬合子宫颈尺寸时,Temp-Bond和Fleck的磷酸锌水泥之间没有观察到统计学上的显着差异。使用不同的制剂设计时,Temp-Bond加上凡士林的平均抗拉伸位移性无统计学差异(p> 0.05),但使用的是20度TOC和8 mm的咬合子宫颈尺寸。对于4种制备设计中的每一种,Temp-Bond和Temp-Bond加凡士林之间的平均抗拉强度均存在显着差异(p <0.05)。在测试的水泥中,IMProv表现出更高的值,这在统计学上是不同的(p <0.05)。咬合口尺寸较大且TOC较小的修复体显示出较高的抗拔抗张性。结论:TOC为20度且咬合面尺寸为8 mm的制剂对所有测试的水泥的平均保持力值均明显较高。观察到平均抗拉强度有显着差异,IMProv观察到最高抗拉强度,其次是Fleck水泥,Temp-Bond加凡士林则观察到最低抗拉强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号