Measurement of bronchoconstriction using whole-body plethysmograph: comparison of freely moving versus restrained guinea pigs.

机译:使用全身体积描记器测量支气管收缩:自由移动和约束的豚鼠的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

We have previously measured pulmonary function in guinea pigs using a double-chambered plethysmograph, however, the question remains regarding the accuracy of the double-chamber to gauge the long-term pulmonary function of late asthmatic response. This may be affected by confounding factors, such as stress on the animal and differences in size of the collar around the neck. Therefore, in this study we compared histamine-induced bronchoconstriction in the same guinea pigs using a single- versus a double-chambered body box. In the double-chambered body box, the specific airway resistance is proportional to time delay between thoracic and nasal flows and measured in cmH2O x s. Whereas, in the single-chambered body box, PenH units (Enhanced Pause) reflect "effort of breathing." This is measured as the pause between inspiration and expiration. Doubling concentrations of histamine (12.5-200 microg/ml dissolved in normal saline) were administered by DeVilbiss nebulizer for 1 min, followed by 1 min suction of residual drug in the chamber, and then the airway resistance was recorded by the computer for the following 3 min. There was a 15-min wash-out period between two doses of histamine. There was no statistically significant difference (p > 0.05) in the PC100 values for histamine between the two methods, however, it was much easier to work with the single-chambered body box in terms of handling the animal and eliminating the possible influence of collar placement on the bronchoconstriction. In conclusion, the data suggests histamine challenges produce equivalent PC100 data in both the double-chambered plethysmograph with sRAW units and single-chambered plethysmograph using the PenH units.
机译:我们之前已经使用双腔室容积描记器测量了豚鼠的肺功能,但是,关于双腔室测量晚期哮喘反应长期肺功能的准确性仍存在疑问。这可能受到混杂因素的影响,例如对动物的压力以及脖子周围项圈大小的差异。因此,在这项研究中,我们使用单腔室和双腔室体箱比较了同一只豚鼠中组胺引起的支气管收缩。在双腔体箱中,比气道阻力与胸腔和鼻腔之间的时间延迟成正比,单位为cmH2O x s。而在单腔体框中,PenH单位(增强的暂停)表示“呼吸努力”。这是吸气和呼气之间的停顿时间。用DeVilbiss雾化器施用1倍浓度的组胺(溶于生理盐水中为12.5-200微克/毫升),持续1分钟,然后将1分钟的残留药物吸入腔室,然后通过计算机记录下呼吸道阻力,用于以下情况: 3分钟两剂组胺之间有15分钟的清除期。两种方法之间组胺的PC100值在统计学上无显着差异(p> 0.05),但是就处理动物和消除衣领的可能影响而言,使用单腔体箱更容易放置在支气管狭窄上。总之,数据表明,在使用sRAW单元的双腔室体积描记器和使用PenH单元的单腔室体积描记器中,组胺激发产生的PC100数据相当。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号