This paper is aimed at assessing analytically the dc corona induced pressures in wire-cylinder and wire-plate electrostatic precipitator configurations. This calls for solving the equations describing the corona discharge and the force balance for static gas equilibrium provided that the corona onset voltage and the space-charge-free field values are calculable. The calculated pressure and potential distributions along the gap axis in air and nitrogen at atmospheric pressure agreed well with those measured previously. The calculated corona current density values agreed reasonably with those measured for a high-temperature high-pressure wire-cylinder precipitator. The analytically calculated positive and negative dc corona onset voltages for wire-duct precipitators following proposed criteria based on discharge physics are in good agreement with those measured experimentally at atmospheric and lower pressures.
机译:本文旨在分析评估线筒和线板静电除尘器配置中的直流电晕感应压力。这要求求解描述电晕放电和静态气体平衡的力平衡的方程式,前提是电晕起始电压和无空间电荷的场值是可计算的。在大气压力下,空气和氮气中沿间隙轴计算的压力和电势分布与先前测得的结果非常吻合。计算出的电晕电流密度值与高温高压线筒式除尘器的测量值合理地吻合。遵循建议的基于放电物理学的标准,对导线式除尘器进行分析计算得出的正负直流电晕起始电压与在大气压和低压下实验测得的电压非常吻合。